Whirlpool 99043751B Instrucciones de instalación y manual de uso y mantenimiento - Página 8
Navegue en línea o descargue pdf Instrucciones de instalación y manual de uso y mantenimiento para Campana de ventilación Whirlpool 99043751B. Whirlpool 99043751B 24 páginas. 24" (58 cm), 30" (76.2 cm), 36" (91.4 cm) range hood
2. To wire through top:
Mark a line 7½" (19.0 cm) from the right of the centerline on
the underside of the cabinet. Mark the point on this line that is
2" (5.0 cm) from back wall. Drill a 1¼" (3.0 cm) diameter hole
through the cabinet at this point.
To wire through rear wall:
Mark a line 7½" (19.0 cm) from the right of the centerline on
the wall. Mark the point on this line that is ¾" (1.9 cm) from
underside of cabinet. Drill a 1¼" (3.0 cm) diameter hole
through wall at this point.
Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm)
Rectangular Vent System
Roof Venting
To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangular cutout
on the underside of cabinet top and bottom:
1. Mark lines 1½" (3.8 cm) and 5½" (14 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
4. Repeat steps 1-3 for the underside of the top of the cabinet
Cabinet cutouts
*From wall, not cabinet frame
8
2" (5.1 cm)
7 ¹⁄₂"
from wall,
(19 cm)
not cabinet
frame
Centerline
³⁄₄" (1.9 cm)
7 ¹⁄₂"
(19 cm)
Centerline
*1¹/₂" (3.8 cm)
*5¹/₂"
5¹/₄"
(14 cm)
(13.3 cm)
5¹/₄"
(13.3 cm)
Wall Venting
To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangle in the wall:
1. Make 2 lines by measuring from floor 65⁷⁄₈" (167.3 cm) and
62³⁄₈" (158.4 cm) or ¹⁄₈" (3.2 mm) and 3⁵⁄₈" (9.2 cm) down from
underside of cabinet and mark on the centerline on the back
wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
Cabinet
front
¹⁄₈"
(3.2 mm)
3 ⁵⁄₈"
(9.2 cm)
Style 2 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm)
Rectangular Vent to 6" (15.2 cm) Round Vent Transition
Roof Venting
To make a 4" x 10½" (10.2 x 26.7 cm) rectangular cutout on the
underside of cabinet bottom:
1. Mark lines 1½" (3.8 cm) and 5½" (14 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
*5¹/₂"
(14 cm)
*From wall, not cabinet frame
To make a 6¹⁄₄" (15.9 cm) circle on the underside of the cabinet
top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line 4³⁄₄" (12.1 cm) from the back wall on the underside
of the top of cabinet.
3. Draw a circle using a compass or 6¹⁄₄" (15.9 cm) circle
template.
Centerline
¹⁄₄
5
"
(13.3 cm)
*1¹/₂" (3.8 cm)
5¹/₄"
(13.3 cm)
5¹/₄"
(13.3 cm)