Whirlpool EXTKIT18FS Instrucciones de instalación y manual de uso y mantenimiento - Página 8

Navegue en línea o descargue pdf Instrucciones de instalación y manual de uso y mantenimiento para Campana de ventilación Whirlpool EXTKIT18FS. Whirlpool EXTKIT18FS 28 páginas. 30" and 36" (76.2 and 91.4 cm) wall‑mount canopy range hood

Whirlpool EXTKIT18FS Instrucciones de instalación y manual de uso y mantenimiento

Connect Vent System

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Install transition on top of hood (if removed for shipping)
with (2) 3.5 x 9.5 mm sheet metal screws.
A
B
A. Vent transition
B. 3.5 x 9.5 mm screw
For vented installations only:
1. Fit vent system over transition piece.
2. Measure from the bottom of the air deflector to the bottom
of the hood outlet. Cut the ductwork at the measured
dimension.
Wall
outlet
3. Seal connection with clamps.
4. Check that back draft dampers work properly.
8
Roof outlet
Wall
outlet

Install Range Hood

NOTE: Remove protective film from range hood and metal filters.
1. Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
B
C
A. Mounting screws
B. Mounting slots
C. Lower mounting screws
2. Remove the grease filter. See "Range Hood Care" section.
3. Level the range hood and tighten upper mounting screws.
4. Install (2) 5 x 45 mm lower mounting screws and tighten.
Use the optional wall anchors if needed.
For non-vented (recirculating) installation only:
1. Assemble the air deflector with the duct cover bracket with
2 assembly screws provided with the Recirculation Kit.
B
A. Vent cover bracket
B. Assembly screws
C. Deflector
2. Measure from the bottom of the air deflector to the bottom
of the hood outlet.
B
D
E
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
A
A
B
C
A
C
X