Whirlpool RH3736XLB3 Instrucciones de instalación y manual de uso y mantenimiento - Página 8
Navegue en línea o descargue pdf Instrucciones de instalación y manual de uso y mantenimiento para Campana de ventilación Whirlpool RH3736XLB3. Whirlpool RH3736XLB3 24 páginas. 30" (76.2 cm) and 36" (91.4 cm) range hood
También para Whirlpool RH3736XLB3: Lista de piezas (1 páginas), Instrucciones de instalación y manual de uso y mantenimiento (24 páginas)
Wall Venting
To make a 4" x 10½" (10.2 cm x 26.7 cm) rectangle in the wall:
1. Make 2 lines by measuring from floor 65 " (167.3 cm) and
62 " (158.4 cm) or
" (3.2 mm) and 3 " (9.2 cm) down from
underside of cabinet and mark on the centerline on the back
wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
Cabinet
front
"
(3.2 mm)
"
(9.2 cm)
Style 2 - Cut Openings for 7" (17.8 cm) Round Vent
System
Roof Venting
To make a 7 " (18.4 cm) circle on the underside of the cabinet
top and bottom:
1. Mark a centerline on the underside of the cabinet bottom.
2. Mark a line " (12.7 cm) from the back wall on the underside
of the top of cabinet.
3. Draw a circle using a compass or 7 " (18.4 cm) circle
template.
4. Use saber or keyhole saw to cut a 7 " (18.4 cm) diameter
opening.
5. Repeat steps 1-4 for the underside of the top of the cabinet.
*5"
(12.7 cm)
*From wall, not
cabinet frame
8
Centerline
5 "
(13.3 cm)
7 / " (18.4 cm) diam.
cabinet cutouts
Style 3 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm)
Rectangular Vent to 7" (17.8 cm) Round Vent Transition
Roof Venting
To make a 4" x 10½" (10.2 x 26.7 cm) rectangular cutout on the
underside of cabinet bottom:
1. Mark lines 1½" (3.8 cm) and 5½" (14.0 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
*5 / "
(14 cm)
*From wall, not cabinet frame
To make a 7 " (18.4 cm) circle on the underside of the cabinet
top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line " (12.7 cm) from the back wall on the underside
of the top of cabinet.
3. Draw a circle using a compass or 7 " (18.4 cm) circle
template.
4. Use saber or keyhole saw to cut a 7 " (18.4 cm) diameter
opening.
7 / " (18.4 cm) diam.
*5"
(12.7 cm)
*From wall, not
Install Vent System
1. Install vent through the vent opening in upper cabinet or wall.
Complete venting system according to the selected venting
method. See "Venting Requirements" section.
2. Use caulking to seal exterior wall or roof opening around the
cap.
*1 / " (3.8 cm)
5 / "
(13.3 cm)
5 / "
(13.3 cm)
Cabinet
cutouts
cabinet frame