Tighten the strain relief screws.
NOTE: Do not reconnect power until the installation is
complete.
OPTIONAL: If you prefer, bend the rear tabs against the rear
of the range hood and attach to the wall using #8-18 x 5/8"
(4.2 x 16 mm) truss-head screws.
11. Connect
Vent System
Connect the ventwork to the range hood.
Seal joints with vent clamps or duct tape to make secure and
airtight.
Check that the back draft dampers work properly.
12. Make
Electrical
Connection
Option 2 - Power Cord Kit Installations
For optional power cord kit installations, follow the instructions
supplied with the power cord kit. See the "Assistance
or Service"
section for information
on ordering.
NOTE: Use only with range hood cord connection kits that have
been investigated and found acceptable for use with this model
range hood. Complete the Installation.
13. Complete
the Installation
A
Option 1 - Direct Wire Installations
Use a UL Listed/CSA Approved wire connector and connect
the 2 white wires (A) together.
Use a UL Listed/CSA Approved wire connector and connect
the 2 black wires (B) together.
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal
box.
Failure to do so can result in death, fire, or
electrical
shock.
Replace the 2 bottom panels.
Position the panel with the small tabs toward the front of
the range hood and the wide flange toward the center of
the range hood. Place the back of the panel into the rear
channel and push the panel toward the back of the range
range hood until the tabs on the front of the panel clear
the front mounting flange.
Slide the panel toward the outside edge of the range
hood and push the front of the panel up until the panel
tabs align with the slots in the front. Release the panel so
the tabs lock the panel in place.
Replace the filter. See the "Range Hood Care" section.
For vented installations: Install a metal filter.
For non-vented (recirculating)
installations: Install a
charcoal filter.
Check the operation of the range hood fan and lights. See the
"Range Hood Use" section.
If the range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect
the power and check the wiring connections.
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Use" section.
Connect the green (or bare) ground wire (C) from the power
supply to the green ground screw in the electrical box and
tighten the screw securely.
Reinstall the electrical box cover.
Reconnect power.