Table 4. Recommended separation distance between potable and mobile RF
communications equipment and the Benesta
The Benesta
Tissue Removal Device is intended for use in an electromagnetic environment in which
TM
radiated RF disturbances are controlled. The customer or the user of the Benesta
Device can help prevent electromagnetic interference by maintaining a minimum distance between
portable and mobile RF communications equipment (transmitters) and the Benesta
Device as recommended below, according to the maximum output power of the communications
equipment.
Rated maximum output
Separation distance according to frequency of transmitter (in meters)
power of transmitter
150 kHz to 80 MHz
d = 1.2√P
0.01
0.12
0.1
0.38
1
1.2
10
3.8
100
12
For transmitters rated at a maximum output power not listed above, the recommended separation
distance d in meters (m) can be estimated using the equation applicable to the frequency of the
transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to
the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
Warranty
Caldera Medical products are warrantied to be free from defects in
•
material and workmanship for the warranty period beginning from the
date of invoice.
This limited warranty is restricted to replacement by Caldera Medical, at
•
its option, of any product found to be defective during the warranty
period.
Damage inflicted to a product by the user will result in additional charges
•
and may void the warranty.
– There are no serviceable components of the Benesta
Removal Device.
– No modification of this equipment is allowed. Modifications may
cause serious injuries to both patient and/or user. Any modifications
will void any warranty and the risk of use is transferred to the user.
– This includes but is not limited to normal use related damage, any
attempted repairs by unauthorized service providers, use of a
sterilization method not approved by Caldera Medical, and use of the
product in a way that is not intended by Caldera Medical.
All warranties apply to the original buyer only and are not transferable.
•
In no event shall Caldera Medical be liable for any anticipated profits,
•
consequential damages or loss of time incurred by the buyer with the
purchase or use of any product.
Refer to the current Caldera Medical Terms and Conditions for full
•
warranty details or contact Customer Service for specific warranty
information.
NO OTHER WARRANTY, EXPRESSED OR IMPLIED, IS GIVEN.
•
Technical Support
For technical support and product return information, please contact
Caldera Medical via email ([email protected]) or telephone, at 866-
422-5337.
TM
Tissue Removal Device
Tissue Removal
TM
Tissue Removal
TM
80 MHz to 800 MHz
800 MHz to 2.5 GHz
d = 1.2√P
d = 2.3√P
0.12
0.23
0.38
0.73
1.2
2.3
3.8
7.3
12
23
Tissue
TM
All Caldera Medical Instruction for Use (IFU) documents are available in print form
at no additional cost upon request. If you would like to request a copy please
contact us at 818.879.6555, fax 818.879.6556,
or email [email protected].
To learn more about Caldera Medical, other products for incontinence,
product evaluations, and training opportunities, contact Caldera Medical at
866.422.5337 or visit our website at www.calderamedical.com.
Benesta is a trademark of Caldera Medical, Inc. and/or its subsidiaries in
the United States.
7