Bacteo Tower BT0H10S10 Manual del usuario - Página 11

Navegue en línea o descargue pdf Manual del usuario para Equipos de iluminación Bacteo Tower BT0H10S10. Bacteo Tower BT0H10S10 11 páginas.

Bacteo Tower BT0H10S10 Manual del usuario
F.A.Q.
1. Does it kill molds and yeasts?
It does, but it would take a much longer exposure time and dose. We do not
recommend using Bacteo for that purpose, as traditional means of cleaning mold and
yeasts would be much more effective.
2. How long should I wait after the disinfection is finished before I can enter the
room?
You can enter the room straight away. Bacteo doesn't generate ozone, so it's safe to
enter the room after the disinfection process is complete.
3. I've been exposed to UV-C lightning by accident. What should I do?
If it's just a short exposure of few seconds – you won't need to do anything unless you
feel negative effects like itching skin or pain in the eyes. If it was a long exposure – you
should seek medical assistance immediately.
4. Should I close the windows and blinds before disinfecting the room?
Yes, definitely. Bacteo is for indoor use only, so please close all windows and shut the
blinds.
5. Is UV-C radiation harmful to other electronics such as TV or a computer?
No, not at all. It's harmful only to the living organisms.
6. The motion detection sensor is constantly turning the lamp off, even though the
room is free of animals and people.
If the motion detection sensor is constantly detecting movement even though there's
none, please do the following:
• Check if the windows are closed by blinds. Movement outside (tree branches,
birds) can be the reason of motion detection.
• If the walls are made of glass, drywall or thin plywood – motion sensor may detect
movement though such walls and stop the disinfection process.
• If none of the above factors are present – it could mean a malfunction with the
sensor. Please contact us at www.bacteo.com/support for further help.

TECHNICAL SPECIFICATIONS

Bacteo Tower
Tower weight and size: 3.8kg / 8.4lb / 28x28x75 cm /
11x11x29,5"
Power supply: 110/240 AC
Sterilization area: up to 60m
Power cable: 5 m (16.4 ft) textile
Motion detection technology: Doppler radar 5.8 GHz
Auto turn-off active zone: up to 10 m (32ft) diameter
or 5m (16ft) radius.
Ambient temperature: 25°C (+/-10°C) / 77°F (+/-18°F)
IP Rating: 20
/ 600 ft
2
2
UV-C lamp
Useful Life: 9000 h
Brand: Philips
Lamp power: 95W
Wavelength: 254 nm
Lamp current (Nom): 0.8A
Voltage (Nom): 115 V
Mercury (Hg) Content (Nom): 4.4 mg
Power factor: 0.98
11