Front panel
1
2
3
Series 579
Supply: 230V (ac) ±10%
Power: 225VA
T
: 5–50°C
AMB
IP 42
Display
The following information normally appears on the display:
B = battery alarm
I = input relay IN1 energized
Probe S1 pressure
From the main display in standby mode, press any key once to activate the display, press again to view the operating status:
Operating status
Measured p
NOTE: to change language refer to menu point 2.2
Symbols used
The symbols shown below are a selection of those displayed during system operation.
Meaning
Strainer with all valves closed and washing
not started
Device filling phase
Drainage phase
Drain valve closing
Plant inlet valve opening
Plant inlet valve closing (with dirty strainer)
Strainers cleaning in progress
Internal functional tests
System not operating, with error 11
(For details of errors refer to the faults table)
Sleep function enabled
Filtration
4
5
6
7
✔
Cale
S.p.A.
S.R. 229 n° 25
28010 Fontaneto d'Agogna
Italy
Day of the week
Display message
2
LED indicators:
1 Red LED:
steady (alarm notification with system locked)
flashing (fault, system operating)
2 Yellow LED: indication of cleaning or additives delivery in
progress or resumption of operations following
reset
3 Green LED: flashing (initial cleaning) steady on (normal
operation)
4 UP button
5 DOWN button
6 BACK button
7 Confirmation/OK button
Time
Probe S1 temperature
Alternate message
Operating status
Measured p