Shock sensor
Sensor Test Mode
This mode will allow you to actively test the shock
sensor and make adjustments without the alarm being
armed. Be sure that the sensor is securely mounted
to the vehicle before entering the Sensor Test mode.
To enter Sensor Test mode:
1. Turn the ignition on.
2. Within 4 seconds, press Button 1.
• The siren will chirp 4 times, indicating that the sensor is ready to be tested.
3. Test the sensitivity. The siren will respond with a short chirp each time an impact is detected.
• The green led on the sensor will turn on when a light (warn away) impact is detected.
• The red led on the sensor will turn on when a heavy (trigger) impact is detected.
4. To make adjustments:
• Turn the adjustment screw on the sensor clockwise to increase the sensitivity.
• Turn the adjustment screw on the sensor counter clockwise to decrease the sensitivity.
5. When you are satisfied with the sensitivity, turn off the ignition.
Starter Defeat / Optional Circuit Defeat
The on-board starter defeat relay is designed for normally closed operation only. Connect the brown wires as shown.
The optional circuit defeat output is programmable for normally closed or normally open operation. Connect the circuit
to be interrupted as shown, then program the orange wire to the desired operating mode.
Starter Defeat
Optional Circuit Defeat