Alde Compact 3020 HE Manual de instrucciones - Página 5

Navegue en línea o descargue pdf Manual de instrucciones para Sistema de calefacción Alde Compact 3020 HE. Alde Compact 3020 HE 19 páginas.
También para Alde Compact 3020 HE: Instrucciones de uso e instalación (8 páginas), Modificación de las instrucciones de instalación (4 páginas)

Alde Compact 3020 HE Manual de instrucciones
5:1
SET THE DESIRED TEMPERATURE
The temperature can be set between +5°C and +30°C, inclusive, in increments of 0.5°C.
NB. If night or day auto is activated (see section 7:1 point 1 and 2) it is not possible to make temperature
adjustments. The plus and minus symbols are then grey.
+22°C
1 kW
5:2
DOMESTIC HOT WATER
The boiler is fitted with a built-in hot water heater which can hold approximately 8.5 litres. The boiler can
equally well be used without there being any freshwater in the heater. There are three different settings
for hot water: no hot water, normal operation and more hot water.
+22°C
1 kW
+22°C
1 kW
+22°C
1 kW
Functions marked with a (*) are accessories, which are not installed on all vehicles, refer to the vehicle
manufacturer's instructions.
1. The temperature displayed is the temperature which is currently set.
2. Increase the temperature by pressing the "+" button. Reduce the tem-
perature by pressing the "-" button.
3. The settings are now complete and the boiler will work at the set
temperature.
1.
No domestic hot water. If domestic hot water is not needed, press the
"-" button (symbol becomes empty).
NB. If night or day auto is activated, see section 7:1 points 1 and 2,
and where hot water is turned off, it is not possible to make hot water
adjustments. The plus and minus symbols are then grey.
2. Normal operation. If there is freshwater in the heater and control of
domestic hot water is required,
press the "+" button (the symbol will then show half-shaded).
NB. If the pump operation function has been set to Cont., see section 7:1
point 17, this option cannot be selected.
Info! When hot water only is required, during the summer for instance,
or when there is no requirement for hot water, no settings need to be
made; the boiler looks after this function automatically.
NB. As the hot water and glycol fluid in the boiler are heated
simultaneously, the hot water can be very hot when a high level of
heating is required.
3. More hot water. If you need more hot water, the water temperature can
be temporarily increased to around 70°C. Press the "+" button so that the
symbol shows fully shaded (black). The boiler returns to normal operation
after 30 minutes. Once you have selected more hot water, the circulation
pump stops.
NB. If the pump operation function is set to Cont., see section 7:1 point 17,
then the continuous pump operation function is turned off for 30 minu-
tes, before then returning to continuous pump operation.
NB. If an additional hot water tank
the panel is in more hot water mode, the hot water function can then be in
operation for longer than 30 minutes.
(*Alde Flow part no. 3020 161)
is installed and
5