INSTALLATION: LYNX ECO DUAL SHOWER RECTANGULAR
Diagram # 1
Install G1/2 male threaded shower outlet at recommended height of 1900mm above the floor of the shower recess.
The resultant height of the RAIN SHOWER is 2200mm
Diagram #2
FULLY unscrew top grub screws from diverter and remove top connector piece (avoid damage to O-rings). Apply
thread tape to the G1/2 male thread then screws on the top connector piece
Diagram #3
Attach the square block plate to the wall using screw / plastic plug supplied. Block plate to be vertically in line with top
connector piece. Groove must be on the same side as grub screw on wall bracket. Grub screw hole in 6 o'clock
position. Vertical distance between top and bottom connections is variable – maximum 620mm
Push bottom rail onto the underside of the diverter – no thread tape required. Do not tighten the 2 grubs screw at
Diagram #4
back of rail completely yet; leave these grub screws slack, but ensure screws are evenly tight.
Diagram #5
Make sure that the grub screws on the top of diverter are wound out. Push the diverter over the top connector piece
and the bottom post over the block
Diagram #6
Tighten the grub screws on the top of diverter and bottom of the rail to ensure secure fit.
Diagram #7
Tighten the 2 grubs screw at back of rail completely ensuring the top and bottom rail are completely vertical and level
Diagram #8
Screw the RAIN SHOWER onto the top arm and attach shower hose to bottom of rail.
Ensure that black sealing washers are in place