Clarity SMB-200 Manual rápido - Página 3
Navegue en línea o descargue pdf Manual rápido para Amplificador Clarity SMB-200. Clarity SMB-200 4 páginas. 200 watt 2-channel power amplifier
All connections should be made to the
amplifier and double-checked before the ac
power cord is plugged in.
The power indicators will illuminate when the ac
power cord is plugged in and the power switch is in
the "ON" position.
OPERATION
General
The SMB-200 provides two modes of operation,
2-channel (100 watts per channel) or 1-channel mono
(200 watts bridged).
When the amplifier is in the 2 channel mode signals
are applied to both the channel A and B inputs.
Channel A and B outputs are connected to their
respective speaker loads. The output levels are
controlled by the channel input volume controls. In
the event that low frequency content is not required to
the speaker load, i.e. paging horns, the contour switch
may be operated to the ON position and frequencies
below 300 Hz will be reduced at a rate of 6 dBm per
octave.
When the amplifier is used in the bridge mode the
switch located on the back of the amplifier is
operated to the bridge mode position. The input
signal is applied to Channel A. The speaker load is
connected between the Channel A and Channel B 2
ohm output terminals. Channel A volume control is
used to adjust the volume level; of the speakers. In
the event that low frequency content is not required to
the speaker load, i.e. paging horns, the contour switch
may be operated to the ON position and frequencies
below 300 Hz will be reduced at a rate of 6 dBm per
octave.
PROBLEM
No output.
Distorted output.
Clipping lights are provided on the front of the unit.
These lights will illuminate when the output signal
exceeds the power rating of the amplifier.
There are 2 power lights located on the front of the
unit that will illuminate when the unit is connected to
a 120 Vac power source and the power switch is in
the ON position.
TECHNICAL ASSISTANCE
When trouble is reported, verify that AC power is
being supplied to the unit and there are no shorts or
grounds on speaker cabling. Assistance in trouble-
shooting is available from the factory. When calling,
you should have a VOM and a telephone test set
available and be calling from the job site. Call (540)
427-3505 and ask for Technical Support. Visit our
website at http://www.clarity-com.com.
CLARITY maintains service facilities in Roanoke,
VA. Should repairs be necessary, attach a tag to the
unit clearly stating company name, address, phone
number, contact person and the nature of the problem.
Send the unit to:
TROUBLESHOOTING CHART
POSSIBLE SOLUTION
1.
Verify AC power is being supplied to the unit and the power switch
is in the "ON" position and both power lights are illuminated.
2.
Verify that input signal is present at amplifier connection.
3.
If speaker controller or equalizer is not being used, make sure that
effects switch is in the "OFF" position.
4.
Verify all speaker wiring (no opens, shorts or grounds).
1.
Check input wiring for proper polarity connections.
2.
Verify that speaker load does not exceed amplifier rating.
3.
Verify input signal does not exceed input voltage rating.
4.
Verify all speaker wiring (no opens, shorts or grounds).
3
Repair and Return Dept.
Clarity
5614 Hollins Road
Roanoke, VA 24019-5056