Power and Control Cable Connections
White. Volt Free / Night Switching (N/O)
Yellow. Volt Free/ Night Switching (COM)
Green Telemetry -
Blue Telemetry +
Red: +ve
Black: -ve
Remote Switching
The Illuminator may be activated remotely by a volt-free contact latched across
the telemetry wires (see Diag above).
Photocell following contact
Volt-free relay contact-normally open (day) to normally closed (night). See Diag
above.
Pot for photocell
adjustment
Pot for power
adjustment
Pressure relief
valve
Power and
control cable
Certifications
This product complies with the European Directive 89/336/EEC
Electromagnetic Compatibility and 73/23/EEC Low Voltage Directive by
meeting the following standards:
Safety:
EN60598-1:2008 Electrical Safety
EN60825-1:2007 LED/Laser Eye Safety
EMC:
EN6100-6-1:2007
EN6100-6-3:2007
EN6100-3-2:2006
EN6100-3-3:1995 AMDI & AMD2
FCC:
FCC CFR Part 15. 107 and 15.109
IP:
IP67 in accordance with EN 60529:1992
AMDI 7643. 1993 AMD2 10931, 2000
WEEE:
Waste Electrical & Electronic Equipment European
directive 202/96/EC
RoHS:
Restriction of Hazardous Substances European
directive 202/95/EC
This symbol on the product means that the electrical and/or electronic
equipment to which it relates should be disposed of at the end of life
separately from domestic household waste.
There are separate collection systems for recycling in the EU. For more
information please contact the Local Authority or supplier of the
product.
Power Adjust
To adjust the power, first unscrew the sealing cap then adjust the power
potentiometer clockwise to increase the power and counter clockwise to turn it
down. The unit is factory set to maximum output.
Photocell
The photocell is designer to automatically switch the lamps on at dusk and turn
off at dawn. A high degree of hysteresis is incorporated to void on/off switching in
marginal conditions. The unit is factory set at approximately 30 Lux On and 70 Lux
Off, but can be adjusted.
Photocell Sensitivity
To adjust the photocell sensitivity first remove the sealing cap, then adjust the
potentiometer to turn the lamp on when lighting conditions are lighter or darker.
Adjust the counter clockwise to make the lamp turn on when it is lighted and
clockwise when it's darker.
Disabling the photocell
To disable the photocell, adjust the sensitivity fully counter clockwise. This will
mount
make the lamp turn on at all times.
Safety
WARNING: When the lamp is running, it is hot to touch, before touching switch off
the illuminator and allow to cool for a minimum of 10 minutes.
Do not stare directly into the lamp at a distance of less than 1.8m
PoE Models
The Clarius PoE/PoE+ series illuminators are powered by Power over the Ethernet
(PoE) via a network cable connector to a PoE IEEE802af/IEEE802at compliant
switch.
The power consumption of the illuminations comply with PoE IEEE802af and
IEEE802at.
These illuminators are not supplied with a power cord. Instead, they are supplied
with a 2.5m (8') long network cable. At the end of the network cable is a female
RJ45 Cat5e compliant connector with an IP68 rated cover.
The mating IP68 rated over is supplied with the illuminator. Follow the instructions
supplied with the cover on how to attached if to the male Cat5e network cable.
ENSURE THAT THE IP68 RATED COVER IS CORRECTLY FITTED AND ATTACHED TO THE
NETWORK CABLE. IF THIS IS NOT FITTED CORRECTLY MOISTURE CAN GET INTO THE
CONNECTOR AND MAY CAUSE THE UNIT TO MALFUNCTION. THIS WOULD VOID THE
WARRANTY ON THE PRODUCT.
T rouble Shooting
Ensure all tests are undertaken by a qualified, trained engineer and
ensure safe working practices are followed at all times.
Step 1: Basics
Check power connection
Ensure power is 12-32V DC / 24V AC
Check the photocell is working - cover photocell ,light should turn
on
Ensure power supply is suitably rated to product - check the
specifications
Step 2: Lamp Test
Check current draw of lamp corresponds to specification
Check current of lamp - see instructions for correct current settings
To check lamp current remove +ve (red) lead from power supply and
connect a multimetre (set to 10A) in line with the lamp. (One lead of
multimeter in common (COM) other lead into 10A socket of multimeter;
set multimeter to read Amps). Refer to PSI Specifications for correct
current settings.
Step 3: Set up Camera, lens and Illumination
Check alignment of lamp
Check camera lens- fully open at night and set correctly
Check model number to performance specification to ensure
required distance is achievable
Step 4: Call for further assistance
If the lamp is still not delivering the required performance, please
contact Technical Support for further assistance
Note down:
Model number and serial number of illuminator
Camera make and model
Lens make and model