WIRING DIAGRAM

Model R80CT-XX
Sleeping Area
Damper
Model R80CT-XX
Living Area
Damper
HVAC System
G
Y
W
C
R
Model C365T11
Thermostat (in Living Area)
R
C
W
Y
G
NC
TS
C365T11
Model TS5
Temperature Sensor for Sleeping Area
Model A80MT
Damper Actuator
CLS
Modulating or
OPN
Open/Close
COM
24VAC,2.4VA
Made in USA
eControls, Inc.
Model A80MT
Damper Actuator
CLS
Modulating or
OPN
Open/Close
COM
24VAC,2.4VA
Made in USA
eControls, Inc.
COM
CLS
OPN
COM
CLS
OPN
TS

WIRING INSTRUCTIONS

!
Warning!
Turn the power to the HVAC equipment off before wiring.
Equipment Wiring
Use 5-conductor, 18 or 20 gage, thermostat cable to wire from
the C365 Thermostat to the equipment.
C365
Wire Color
Terminal
R
Red
C
Blue
W
White
Y
Yellow
G
Green
NC
NO CONNECTION TO THIS TERMINAL
Damper Wiring
Use 3-conductor, 18 or 20 gage, thermostat cable to wire from
the C365 Thermostat to the upstairs sleeping and downstairs
living area dampers. There are separate terminals for the
sleeping and living dampers.
Ensure the damper in the sleeping area is wired to
the terminals labeled SLEEPING and damper in the
living area is wired to the terminals labeled LIVING.
C365
Wire Color
Terminal
COM
White
CLS
Red
OPN
Green
Multiple dampers can be used to construct the sleeping or
living zones. Daisy chain terminals– COM to COM, OPN to
OPN and CLS to CLS.
Temperature Sensor Wiring
Use 2-conductor, 18 or 20 gage, thermostat cable to wire from
the C365 Thermostat to the temperature sensor in the sleeping
area.
One or two temperature sensors can be used in the sleeping
area and the temperatures are averaged.
Single Sensor Installation
Use one (1) Model TS510W sensor.
Dual Sensor Installation
Use two (2) Model TS520W sensors.
C365
Wire Color
Terminal
TS
White
TS
Red
3
Equipment
Function
Terminal
R, Rc, Rh
24VAC Power
C
Common
W, W1
Heating
Y, Y1
Cooling
G
Fan
Damper
Function
Terminal
COM
Common
CLS
Closes damper
OPN
Opens damper
Sensor
Function
Terminal
SNR
Thermistor
SNR
Thermistor