Upper Extrusion
(Adjustable Angle)
Lower
Extrusion
(Stationary)
Mounting Clip
(ALS600T-AD-MC)
FEATURES
APPLICATIONS
LAMP TYPE
CRI
LENS
OPTICS AND ASYMMETRIC
LENGTH
CONSTRUCTION
WEIGHT
MOUNTING
LISTING
INSTALLATION
ELECTRICAL
DIMMING
MAXIMUM RUN
(Line Voltage)
MAXIMUM RUN
(Remote Driver)
PRIMARY VOLTAGE
SECONDARY VOLTAGE
TEMPERATURE RATINGS
ELECTRICAL
• Line voltage luminaire do not require a remote driver
• Calculate Load (Driver/Power Supply)
To calculate load, multiply watts per foot by length. Example: 4 Watts x 4' = 16 Watts
• Maximum load per line voltage fixture = 320 watts per circuit
• Maximum load per low voltage fixture (JA8) = 50 watts per circuit
CALIFORNIA ACCENT LIGHTING, INC.
2820 E. Gretta Lane, Anaheim, CA 92806
ph. 800.921.CALI (2254) | fx. 714.535.7902 | [email protected] | calilighting.com
© CALI. All rights reserved. CALI reserves the right to make changes or withdraw specifications without prior notice.
2019.12.5 Rev 2
LED with Optics
(Included)
Tempered Clear Glass Lens
(ALS600T-AD-CGL)
Power Connector
(ALS600T-AD-PC)
Wall Wash Lighting
High Output LEDs (No Mercury)
> 90
Tempered Clear Glass Lens
10°-60° and Asymmetric Optics
1'6" , 2', 3', 4'
Aluminum Extrusion
2.52lbs (1'), 4.92lbs (2'), 6.95lbs (3'), 8.98lbs (4')
Mounting Clips
Dry or Wet (IP65 or IP67) Location
UL1598, CSA C22.2#250.0
UL8750, CSA250
UL2108, CSA C22.2 #9
Link to Installation Instructions
0-10V
40' (3W, 6W), 35' (9W), 26' (12W), 21' (15W), 17' (18W)
14' (3W), 7' (6W), 5' (9W), 3'6" (12W), 3' (15W), 2'6" (18W)
120V or 277V
24VDC
Operating / Startup: -20° to 48°C (-4° to 120°F)
Storage: -40° to 76°C (-40° to 170°F)
ALS600T-AD
READ ENTIRE GUIDE BEFORE STARTING INSTALLATION
IMPORTANT NOTICE:
VERIFY CORRECT LUMINAIRE WAS RECEIVED WITH
CORRECT COLOR TEMPERATURE AND VOLTAGE BEFORE CUTTING OR INSTALLING.
CALI WILL NOT BE RESPONSIBLE IF INCORRECT LUMINAIRE IS INSTALLED.
PRODUCT INFORMATION
• Lighting for coves, undercabinet, accent, displays
• Line Voltage or Low Voltage (integral or remote transformer drivers)
• Choose from a variety of LED colors and whites
• Available in 3 Watts up to 24 Watts Per Foot (product is shipped in 1', 2', 3', and 4' luminaires)
• Available for outdoor rated installations
INSTALLATION RECOMMENDATIONS
• AlumLEDs can be mounted to sheetrock, concrete, or wood using proper mounting screws
• All wiring is enclosed inside aluminum housing
• Provide run lengths at time of order
• AlumLEDs is suitable for indoor (Dry) or outdoor (IP65 or IP67) applications
INSTALLATION TOOLS REQUIRED
• Electric Hammer Drills (optional)
• 14.4 to 28 Volt Cordless Drills
• Phillips Bits - Sufficient Quantity
• Utility Knife
• Electrical Cords
• Marker
• Wire Strippers
alumLEDs
Page 1 of 11
INSTALLATION
Overview
• Long Nose Pliers
• Drill Bits - Concrete or Wood
• Electrical Three Ways
• Safety Glasses
• Measuring Tapes
• Chalk Line