Ecoplus 1/2 HP Manual de instrucciones - Página 9

Navegue en línea o descargue pdf Manual de instrucciones para Enfriador Ecoplus 1/2 HP. Ecoplus 1/2 HP 12 páginas. Water chillers
También para Ecoplus 1/2 HP: Manual de instrucciones (12 páginas)

Ecoplus 1/2 HP Manual de instrucciones
Before
calling
service, check the
troubteshooting chart
below
tor
solutions to
the
most
commnn
problems.
SYMPTOM
CAUSE
SOLUTION
Chiller
doesn't
run
Display is blank
Power is not
turned
on
Turn on
the power
Not plugged all the
way
in
Be sure
the power cord
is
fully
plugged
in
Fuse has blown
Change fuse
Chiller keeps
tuming
itself
on and
off
Connected to wrong
voltage and
frequency
Apply
to correct power
source
according
to the
nameplate
Protection device
has been activated
A.
Check
water
circulation
B. Check ventilation
around
unit.
lf
heat is not accumulating,
wait 3
minutes
and
unit will
automatically
restart
Water not cooling
enough
(or not
at all)
Water temperature setting
is
too
high
Lower water temperature
setting
Total water volume
too
high
Reduce water volume
Air
filters
are clogged
with dust
Clean air
filters
as directed
on
Page
7
Not
enough
refrigerant
Have
qualified
personnel
replenish refrigerant
Compressor runs normally,
but fan stops running and
unit can't
dissipate
heat
Fan may need
to
be replaced
by qualified service personnel
Unit is noisy
and/or
rattles
The base is not
flat
Mount it
on
a
flat
base