BEFORE USE

WARNING: COMPRESSED AIR CAN BE DANGEROUS. ENSURE THAT YOU
ARE FAMILIAR WITH ALL PRECAUTIONS RELATING TO THE USE OF AIR
COMPRESSORS AND COMPRESSED AIR SUPPLY.
NOTE: Ensure the compressor is turned off.
1. If required, connect an in-line mini oiler to the tool.
• A mini oiler helps to prolong the life of the air tool.
2. If a mini-oiler is not being used, run a few drops of oil through the tool
before use. It can be entered through the airline connector or via the hose
at the nearest connection to the air supply.
3. Connect a suitable hose as shown.
4. Connect the other end of the hose to the compressor.
5. Turn on the air supply and check for air leaks. Rectify any found before
proceeding.
• PTFE tape may be useful for sealing threaded connections.
Your air tool is now ready for use.

OPERATION

FITTING THE NEEDLE HOLDER

The Scaler is packed in two halves.
1. The main body and hammer assembly
2. The needles with needle holder, needle tube and spring
The needles, needle holder and spring, are inserted in the Needle Tube in the
manner shown in fig. 1, ensuring the Needle Holder is the correct way round,
so that the heads of the Needles sit snugly in the recesses provided in the
Holder.
Push the needle tube, complete with needles, needle holder and spring, on to
the main body so that the retaining lug, in the body, enters the slot in the side
of the tube, shown in fig. 1. Continue to push against spring pressure until the
body may be twisted, and thereby locked, into one of three positions.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
6