ELECTRICAL CONNECTIONS

Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through an approved
13 amp BS 1363 plug, or a suitably fused isolator switch.
IMPORTANT: The wires in the mains lead are coloured in accordance with the following code
As the colours of the flexible lead of this appliance may not correspond with the coloured
markings identifying terminals in your plug proceed as follows:
Connect GREEN & YELLOW coloured cord to plug terminal marked with a letter "E" or Earth
symbol "
" or coloured GREEN or GREEN & YELLOW.
Connect BROWN coloured cord to plug terminal marked with a letter "L" or coloured RED.
Connect BLUE coloured cord to plug terminal marked with a letter "N" or coloured BLACK.
If this appliance is fitted with a plug which is moulded onto the electric cable (i.e. non-rewirable)
please note:
1. The plug must be thrown away if it is cut from the electric cable. There is a danger of
electric shock if it is subsequently inserted into a socket outlet.
2. Never use the plug without the fuse cover fitted.
3. Should you wish to replace a detachable fuse carrier, ensure that the correct replacement
is used (as indicated by marking or colour code).
4. Replacement fuse covers can be obtained from your local dealer or most electrical stockists.
5. The fuse in the plug must be replaced with one of the same rating (5 amps) and this
replacement must be ASTA approved to BS1362.
Important: If a cable extension is needed, it is essential to comply with the following data.
WARNING! THIS APPLIANCE MUST BE EARTHED
Green & Yellow - Earth
Voltage
Extension length
230v
230v
From 20 to 50m
Blue - Neutral
Brown - Live
Up to 20m
6
Cable section
2
2.5mm
4mm
2