Zanussi ZGG 642 Manual de instrucciones - Página 13

Navegue en línea o descargue pdf Manual de instrucciones para Placa Zanussi ZGG 642. Zanussi ZGG 642 20 páginas. Gas hobs
También para Zanussi ZGG 642: Manual de instrucciones (16 páginas), Manual de instrucciones (16 páginas), Manual de instrucciones (20 páginas), Manual de instrucciones (16 páginas), Manual de instrucciones (16 páginas), Manual de instrucciones (16 páginas)

Zanussi ZGG 642 Manual de instrucciones

Wiring Diagram

L
A
Brown
N

Fault Finding

Preliminary Electrical Systems
Check
Blue
Green
Yellow
Blue
Green
Brown
Yellow
1
2
0
3
4
220/240
5
6
B
START
Isolate appliance
and carry out:
A: Earth Continuity
check.
NO
YES
Has inlet fuse blown?
NO
YES
Inlet wiring
faulty.
Rectify any
fault.
Isolate appliance and
carry out:
B: Insulation check.
Rectify any fault
including replacing
fuses as necessary.
A. IGNITOR SWITCH
B. IGNITOR UNIT
PLUG (with cover
removed)
Earth Wire
Green/Yellow
Neutral Wire
Blue
Carry out:
Carry out:
D: Resistance to
C: Polarity check.
Earth check.
A. EARTH CONTINUITY CHECK - Appliance must be
electrically disconnected - meter set on Ω (Ohms) x
1 scale and adjust zero if necessary.
a) Test leads from any appliance earth point to earth
pin on plug. Resistance should be less than 0.1
ý (Ohm), check all earth wires for continuity and
all contacts are clean and tight.
B. INSULATION CHECK - Appliance electrically
disconnected, all switches ON.
a) meter set on Ω(Ohms) x 1 scale.
Test leads from L to N in appliance terminal block.
If meter reads «0» then there is a short circuit.
b) meter set on Ω (Ohm) x 100 scale.
Repeat test with leads from L to E. If meter reads
less than × (infinity) there is a fault.
NOTE - Should it be found that the fuse has failed
but no fault is indicated - a detailed continuity check
(i.e. by disconnecting and checking each
component) is required to trace the faulty component.
It is possible that a fault could occur as a result of
local burning/arcing but no fault could be found under
test. However a detailed visual inspection should
reveal evidence of burning around the fault.
SOCKET
(face view)
( )
N
Electricity supply
should now be
satisfactory.
( )
E
L
13