Zanussi ZGH62414WA Manual del usuario - Página 16

Navegue en línea o descargue pdf Manual del usuario para Placa Zanussi ZGH62414WA. Zanussi ZGH62414WA 21 páginas.
También para Zanussi ZGH62414WA: Manual del usuario (21 páginas)

Zanussi ZGH62414WA Manual del usuario
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER
Rapid
Semi-rapid
Auxiliary
WARNING! This appliance does not
function with the existing gas settings
if installed in Malta. Therefore, before
connecting the appliance it is essential
to change the nozzles according to the
type of gas used according to the
table below.
GAS BURNERS FOR LPG G30/G31 28-30/37 mbar
NORMAL
BURNER
POWER kW
Rapid
2,8
Semi-rapid
2,0
Auxiliary
1,0
Data in the table is specified for Malta.

ENERGY EFFICIENCY

PRODUCT INFORMATION ACCORDING TO EU 66/2014
Model identification
Type of hob
Number of gas burners
Energy efficiency per gas burner
(EE gas burner)
16
NORMAL POWER kW MINIMUM POWER kW
3,0
2,0
1,0
MINIMUM
POWER kW
0,75
0,45
0,33
Left rear - Semi-rapid
Right rear - Semi-rapid
Left front - Rapid
Right front - Auxiliary
0,75
0,45
0,33
NOMINAL GAS FLOW g/h
INJECTOR
MARK
G30 28-30 mbar
86
204
71
145
50
73
INJECTOR MARK
119
96
70
G31 37 mbar
200
143
71
ZGH62414WA,
ZGH62414XA,
ZGH62414XS
Built-in hob
4
57.5%
57.5%
58.0%