POSITIONING

The appliance belongs to the class "X".
It has been designed to be placed close to furniture
able to withstand more than 75 C added to the room
temperature and not exceeding the height of the
working level (CEI 61- 80).

LEVELLING

The appliance is provided with adjustable small feet
placed in the back and front corners od the base.
By adjusting the small feet (fig. 23) it is possible to
change the height of the appliance so as to ensure a
better levelling with othor surfaces and a uniform
distribution of the liquids contained in pans anci pota.
48

BALANCING THE LID

The models that come with crystal lids are equipped
with specially balanced springs.
These are inserted in the hinges at the back of the
appliance to allow the lid to be closed smoothly and
easily.
You can use a screwdriver to adjust the closure of the
lid. The necessary force for opening/closing the lid can
be increased by turning the adjusting screw 2 or 3
times as shown in Fig. 24.

GAS CONNECTION

Gas connection must be carried out according to the
rules UNI - CIG 7129 - 7131.
Fig. 23
The manufacturing company release the unit, once
tested, adjusted for the kind of gas stated on the rating
plate located on the back of the range, next to
connection pipe. Be sure that you are going to connect
the unit to the same kind of gas written on the plate.
Otherwise, follow all the instructions of the paragraph
"REGULATION TO DIFFERENT KINDS OF GAS".
For best efficiency and lowest consumption, be sure
that manifold gas pressure respects the values in the
table of "Burners characteristics".
If gas pressure is different (or variable) from the proper
one, a suitable pressure regulator should be installed
on feeding pipe.
The use of pressure regulators for liquid gas (LPG) is
allowed provided they are modelled in conformity with
the regulations UNI-CIG 7432.
Fig. 24