the performance of the machine, and even
shorten its life.
To clean the air intake filter, carefully remove the
sponge element shown in Fig. 3. clean the sponge
and the housing using a brush and/or clean lint
free cloth.
If necessary, the sponge may be gently washed
in warm soapy water, it must be rinsed and
allowed to dry thoroughly before refitting.
Every 500 hours of operation or every 6 months
Clean all the external parts of the compressor.
(This cleaning makes the cooling process more efficient and prolongs the life of the
machine).
Examine the non-return valve and renew if
necessary (fig. 4) (Item 55, page 9/10,)
In the event of an air leak follow the procedure
below:
• Load compressor to maximum pressure
• Unplug the compressor
• With a brush and soapy water wet all 'screwed' air connections
• Any leaks will show through the formation of air bubbles.
WARNING
NEVER unscrew a connection whilst the air receiver is under pressure.
ALWAYS make certain that the tank has been emptied.

ACCESSORIES

Your Clarke Pioneer Oil Free Air Compressor can be used in conjunction with a wide range
of optional accessories for inflating tyres, air brushing, stapling, blowing and many other
uses. For details contact your local accessory stockist.
A suitable Spraygun and air hose is available for use with your Pioneer 210 oil free
compressor, part numbers as follows.
Spraygun PS .............................................. Part No. 5080813
Hose JP3 .................................................... Part No. 3120203
A wide range of accessories is available from your nearest CLARKE dealer, for further
information, contact your nearest dealer, or telephone CLARKE International Sales
department on 01992 565300.
Fig. 3
Fig. 4
- 7 -

TROUBLE SHOOTING

With considerate use, your CLARKE Air Compressor should provide you with long and trouble free
service. Routine checks should be made on both the electrical supply as well as the compressed
air lines and connections. If any fault appears, the reason for which is not immediately obvious,
please contact your local CLARKE Dealer.

The compressor

Bad connections.
stops and will not
start again.
Overload cutout switch
has tripped.
Motor windings burnt out.
The compressor
Compressor head gasket
does not reach the
blown or valve broken.
set pressure and
Worn Piston
overheats easily.
Compressor does
Air receiver charged
not start.
Air leaking from the
Faulty non-return valve.
pressure switch valve
when the compressor
is not running.
Air pressure from
The diaphragm within the
regulator will not
regulator body is broken.
adjust.
IMPORTANT:
The use of parts other than CLARKE replacement parts may result in safety hazards,
decreased tool performance and may invalidate your warranty.
CAUTION Do not attempt any repair or adjustment if you are uncertain as to how it should be done.
If you have any queries, contact your local CLARKE Dealer.
Check electrical connections.
Clean and tighten as necessary.
Switch off and wait 5 minutes
before switching on.
Contact your local dealer for a
replacement motor.
Contact your CLARKE dealer.
Replace Piston (contact your
CLARKE dealer)
Open drain cock to expel air.
Compressor should start again
when pressure reduces to approx.
First drain the receiver completely.
Replace non-Return Valve
Replace Regulator