Clarke Raider 105 Manual de instrucciones de uso y mantenimiento - Página 12

Navegue en línea o descargue pdf Manual de instrucciones de uso y mantenimiento para Compresor de aire Clarke Raider 105. Clarke Raider 105 17 páginas. 3hp direct drive compressor

Clarke Raider 105 Manual de instrucciones de uso y mantenimiento

TROUBLESHOOTING

CAUTION: DO NOT ATTEMPT ANY REPAIR OR ADJUSTMENT IF YOU ARE
UNCERTAIN AS TO HOW IT SHOULD BE DONE. IF YOU HAVE ANY QUERIES,
CONTACT YOUR CLARKE DEALERMACHINE MART.
PROBLEM
The compressor
stopped and
does not start.
The compressor
does not reach
the set pressure
and overheats
easily.
Compressor does
not start.
Air leaking from
the pressure
switch valve
when the
compressor is not
running.
Air pressure from
the regulator will
not adjust.
The compressor is
very noisy and
makes a metallic
knocking sound.
PROBABLE CAUSE
Bad connections.
Overload cutout switch has
tripped or duty cycle has
been exceeded.
Motor windings burnt out.
Compressor head gasket
blown or valve broken.
Air receiver charged
Faulty non-return valve.
The diaphragm within the
regulator body is broken.
Compressor damaged and
needs overhaul.
REMEDY
1. Check electrical connections.
2. Clean and tighten as
necessary.
1. Switch off and wait approx 5
minutes.
2. Press the reset button and
switch on again.
1. Contact your Clarke dealer for
a replacement motor.
1. Wait for compressor to cool
down,
2. Disassemble head gasket
3. Replace any broken
components.
4. Carefully clean all sealing
surfaces before reassembling.
If in doubt contact Your Clarke
dealer.
1. Open drain valve to expel air.
Compressor should start again
when pressure reduces.
1. Drain receiver completely of
air.
2. Remove the valve end plug,
3. Carefully clean the valve seat
and the gasket
4. Reassemble.
1. Replace regulator
1. Return the machine to your
nearest service agent.
12