SYMPTOM
Compressor
becomes too
hot.
Compressor
unit runs on
and off load
more
frequently
than usual.
Compressor
unit runs 'on
load' when
no air is being
used.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
PROBABLE CAUSE
Insufficient ventilation.
Oil level too low (check 2 or
3 minutes after stopping.
Fault in valves (machine not
stopping).
Blown head gasket (machine
not stopping).
Dirt on cooling fins or suction
filter.
Unit working at too high a
pressure.
Not fully unloading
Load genie partly blocked.
Large amount of
condensation in air receiver.
Leaks in system
Leaks in system
REMEDY
See that sufficient air is
supplied to flywheel or fan
of compressor and that
hot air is properly vented.
Fill with oil
Contact Clarke Service
Department
Contact Clarke Service
Department
Clean cooling fins and
suction filter.
Contact Clarke Service
Department
Contact Clarke Service
Department
Contact Clarke Service
Department
Drain off condensation
Regularly (Every day
before use).
Locate leaks (by means of
soapy water) and repair.
Locate leaks (by means of
soapy water) and repair.