Aleko AC 1500 Manual del usuario - Página 10

Navegue en línea o descargue pdf Manual del usuario para Abrepuertas Aleko AC 1500. Aleko AC 1500 16 páginas. Sliding

Aleko AC 1500 Manual del usuario

Installation of Magnets for Limit Switches

Before install limit switch, make sure the
gate opener is put in manual operation. (the
clutch
connected
with
gear
shaft
is
disengaged) and the mains power supply is
disconnected.
Position the two Magnet Components
approximately on the gate and move the
gate by hand to fix them in place.
Fit magnets bracket
Push the gate fully closed by hand. Locate
and install the magnet bracket so that the
opener will stop at the desired close position
when the close limit switch approaches it.
Push the gate fully open by hand. Locate
and install the magnet bracket so that the
opener will stop at the desired open position
when the open limit switch approaches it.
The magnet component with N pole outside must be installed at left side and the
magnet component with S pole outside must be installed at right side from the view
inside of property.
Finally adjust the magnet to the proper position by moving the gate with the motor. The magnet should be
less than 1"away from the magnetic limit switch. If it is too far away, the switch will fail to work. The distance
between the magnet and the opener should be 0.39"- 0.59" with the opener cover on. Adjust the position of
the magnet until the positions of the opening and closing meet the requirement.
9