CFT12 & CFT24
Ensure the battery is the right type for the pump; ie. 12V for the CFT12 and
24V for the CFT24.
Ensure also that the battery terminals are clean, and, bearing in mind the
warning above, firmly attach the RED clamp to the POSITIVE and the BLACK
clamp to the NEGATIVE terminals respectively. Double check to ensure the
clamps cannot be disturbed easily, and that the setup is protected from
passers by. Set the switch, at the rear of the terminal box, to ON (I).
With the motor running, pull the nozzle trigger and proceed to pump your
diesel fuel. A trigger lock is provided, simply pull the trigger fully, push IN the
lock then relaease the trigger.
Do not allow the pump to operate for more than 30 seconds or so, when
pumping has ceased.

THERMAL OVERLOAD PROTECTION

The motors of these pumps are provided with thermal overload protection.
In the event that the pump cuts out due to overheating, always investigate
the cause - this could be a blocked hose or damage to the pump motor.
The 230V model will restart automatically once it has cooled down
sufficiently. Nevertheless, you should ALWAYS switch the pump OFF and allow
it to cool down.
The battery operated pumps are provided with a reset button, mounted on
the front of the terminal box. Leave the pump to cool down for at least 10
minutes before pressing, to restart the pump.
If the condition persists, further investigation is required to determine the
cause.

MAINTENANCE

The pumps are of robust design and require little or no maintenance, except
for ensuring that the electric power cables and clamps are always in good
condition. Avoid using solvents if cleaning plastic parts as most plastics are
susceptible to damage from various types of commercial solvents.
Ensure also that the hoses used are perfectly sound.
Store the pump in dry conditions protected from the weather.
For any problems requiring the dismantling and overhaul of the saw, contact
your CLARKE International Service Department on 020-8988-7400. Spare parts
are available as shown in the diagrams on the following pages.
Parts & Service: 020 8988 7400/E-mail:[email protected] or [email protected]