Clarke STP12 Manual de instrucciones de uso y mantenimiento - Página 3
Navegue en línea o descargue pdf Manual de instrucciones de uso y mantenimiento para Bomba de agua Clarke STP12. Clarke STP12 9 páginas. Submersible transfer pump
ENVIRONMENTAL RECYCLING POLICY
Through purchase of this product, the customer is taking on the
obligation to deal with the WEEE in accordance with the WEEE
regulations in relation to the treatment, recycling & recovery and
environmentally sound disposal of the WEEE.
In effect, this means that this product must not be disposed of with general
household waste. It must be disposed of according to the laws governing
Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal
facility.
CONTENTS
12 Volt Submersible Pump (with 3.8 m
supply cable with crocodile clips)
15mm metal delivery tube
Please check the contents to ensure they are complete and that no transit
damage has occurred.
Should any damage be apparent, please contact your Clarke dealer
immediately.
SPECIFICATIONS
Flow Rate
Minimum Water Depth
Pump Outlet Size
Voltage
Current
Pressure
Height
Diameter
Weight
Duty Cycle
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
2 x hose clips
3m delivery hose
21 litres/min. for diesel and kerosene
19 litres/min. for clean water
40 mm
19 mm (external diameter)
12 V
4.5A DC
0.23 bar
160 mm
55.5 mm
0.67 kg
15 mins on, 15 mins off in 30 min cycle
3