Alemite 8592 Manual de servicio - Página 3
Navegue en línea o descargue pdf Manual de servicio para Equipamiento industrial Alemite 8592. Alemite 8592 8 páginas. Portable used fluid drain
8592
Purging The Tank
It may not be possible to safely purge the tank of solids and
sediments on the tank bottom using the suction of an Evacuation
System. We recommend the following steps to completely purge the
tank bottom of sediments:
1. Evacuate the tank off all fluids using an Evgacuation System.
2. Remove plug (2) on the Lower Connection (3).
3. Flush tank with water on normal detergent until tank bottom is
free of all solids and sediments.
4. Reinstall Plug (2) and check for leaks.
5. Upon completion of the tank purge, turn Camlock Fitting (20)
clockwise as far down as possible to reset the Suction Tube (22)
height.
Alemite, LLC
Portable Used Fluid Drain
Specifications
Tank Capacity
Top of Sight Gauge
Drain Bowl Capacity
Height at Highest Position
Height at Lowest Position
Table 1 – Model 8592 Specifications
3
105.7 Qt (100 L)
95 Qt (90 L)
17 Qt (16 L)
78 in (198 cm)
51 in (130 cm)
02-2020