Clarke TFC 400 Manual del usuario - Página 10
Navegue en línea o descargue pdf Manual del usuario para Máquina de suelo Clarke TFC 400. Clarke TFC 400 13 páginas.
MAINTENANCE
1)
Use only approved chemicals at the recommended mix ratios. All chemicals
should be added through the feed system and NOT added directly to the water in
the solution tank to prevent possible damage to the pump, seals, or other
components.
2)
For optimum performance, fl ush the Chemical Feed lines after every job by
replacing the chemical containers with containers of clear water and spraying
through the gun until the fl uid stream is clear. See the Maintenance Schedule,
below.
3)
The pump seals and/or valves in the high pressure pumps may need to be
replaced after about 1000 hours of use, if the pump begins to loose
performance or to leak. The pressure regulator valve may need to be when a drop
in the spraying pressure at the tool is apparent.
4)
If the 4", clear lid is removed from the top of the base (solution tank), you will
need to apply a silicone sealant to the threads when you reinstall the lid to seal for
vacuum leaks.
ITEM
Flush chemical lines
Check/clean vac inlet fi lter
Clean solution fi lter
Check vacuum motor airways
Check pump for leaks
Check vacuum motor brushes *
* Have
Clarke
TECHNICAL SPECIFICATIONS
Vacuum motor:
Tank constructions:
Solution tank capacity:
Recovery tank: capacity:
Application fl ow:
Vac & Solution hose length:
Power cord:
Machine weight:
MAINTENANCE SCHEDULE
check the carbon brushes once a year or after about 500 hours of operation.
2-stage, 8 amp
Water lift:
97"
Air fl ow:
100 CFM
Rotationally molded polyethylene
20 gallon
13 gallon
400 psi
25 feet
25 feet
Height:
38.5 inches
Width:
21.25 inches
Length:
34 inches
92 lbs
DAILY WEEKLY QUARTERLY YEARLY
x
x
x
x
10
x
x