2. If no line lubricator is used, ensure that oil is applied to the tool on a daily
basis through the air inlet connection.
3. For lubricating the air motor, an air line lubricator should be used,
containing Clarke Air Line Oil, adjusted to 2 drops per minute. If this is not
possible, run a few drops of oil through the tool. It may be entered into
the tool air inlet, (ensuring the strainer is clear), or into the hose at the
nearest connection to the air supply. Then operate the tool.
Clarke Airline Oil is available from your CLARKE dealer, Part No 3050825.
CLEANING
1. Keep the body of the tool clean and free from debris.
2. Grit or gum deposits in the tool may also reduce efficiency. This condition
can be corrected by cleaning the air strainer and flushing out the tool
with gum solvent oil, or failing this, the tool should be disassembled,
thoroughly cleaned, dried and reassembled.
3. After extensive use, remove the
inlet screen filter and flush out the
mechanism with gum solvent oil
or an equal mixture of SAE No10
oil and paraffin. Allow to dry
before use.
4. Clean the air inlet filter screen
inside the hose adaptor.
5. If the tool runs erratically or
becomes inefficient, and the air
supply is of good quality, it may
be necessary to dismantle the air motor and replace worn or damaged
parts. You may prefer to take the tool to your CLARKE dealer if internal
maintenance is required.
Your Clarke cut-off tool has been designed to give long and trouble free
service. If, however, having followed the instructions in this booklet carefully,
you encounter problems, take the unit to your local Clarke dealer.

SERVICE AND REPAIRS

1. Keep the tool clean at all times, and ensure that the bolts securing the
case remain tight.
• All bearings etc, in this machine are lubricated with sufficient high grade
lubricant for the machines lifetime under normal operating conditions,
therefore no further lubrication is required.
• Be aware that outside factors may effect operation and efficiency, These
may include reduced compressor output, excessive drain on the airline,
moisture in suspension or restrictions in the line, or the use of connectors of
improper size or poor condition which will reduce air supply.
Parts & Service: 020 8988 7400/E-mail:[email protected] or [email protected]