Clarus 6000 Series Manual del usuario - Página 2
Navegue en línea o descargue pdf Manual del usuario para Unidad de control Clarus 6000 Series. Clarus 6000 Series 4 páginas. Automatic multizone valve
Manufacturer warrants, to the purchaser and subsequent owner during the
warranty period, every new product to be free from defects in material and
workmanship under normal use and service, when properly used and maintained,
for a period of one year from date of purchase by the end user, or 18 months
from date of original manufacture of the product, whichever comes first. Parts
that fail within the warranty period, one year from date of purchase by the
end user, or 18 months from the date of original manufacture of the product,
whichever comes first, that inspections determine to be defective in material or
workmanship, will be repaired, replaced or remanufactured at manufacturer's
option, provided however, that by so doing we will not be obligated to replace an
entire assembly, the entire mechanism or the complete unit. No allowance will
be made for shipping charges, damages, labor or other charges that may occur
due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any material
or product that has been disassembled without prior approval of manufacturer,
subjected to misuse, misapplication, neglect, alteration, accident or act of God; that
has not been installed, operated or maintained in accordance with manufacturer's
installation instructions; that has been exposed to outside substances including
but not limited to the following: sand, gravel, cement, mud, tar, hydrocarbons,
hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other abrasive or corrosive
substances, wash towels or feminine sanitary products, etc. in all applications
other than in raw effluent pumping applications. The warranty set out in the
1.
Valve Top: A high strength metal die cast top which is secured to the valve body by eight stainless
steel screws.
2.
Valve Body: A high strength metal die cast housing.
3.
Inlet: Female 1 ½" NPT inlet for connection to water source.
4.
Vacuum Breaker Port: Used to prevent back-siphon of water to course.
5.
Valve Bottom: High strength ABS plastic bottom which is secured to a valve body with 6 stainless
steel screws.
6.
Outlets - Allows for slip and glue connection to 1 ½" PVC pipe.
Replacement cams are available to increase or decrease the number of outlets to be used on the 6000 Series Automatic Multizone Valve. 6400 Series four outlet
valves have interchangeable cams for two, three or four zone operation. 6600 Series six outlet valves have interchangeable cams for five or six zone operation.
To replace cam, first remove valve top by removing eight valve top retaining screws. Remove two cam retaining screws which hold cam on the underside of the valve
top.
Insert replacement cam into valve top, ensuring that the wide notch on came is aligned with notch on valve top, and secure with two cam retaining screws.
Replace top, ensuring body seal is in place.
Prior to installation of 6000 Series Automatic Multizone Valve, make sure that the system is designed using adequate pipe sizes and control valves to ensure maximum
performance of the valve.
For installation with large terrain elevations, or applications with high lift requirements such as overhead systems in greenhouses, the valve should be installed at the
highest point in the system, or check-valves should be installed near the valve in the elevated lines to prevent the back flow of water from the higher locations to the
lower zones.
When connecting the lines to the valve outlets, ensure that the correct cam is installed. See diagram for proper zone hookup of outlets.
Do NOT turn the valve upside down when gluing the lines into the open valve outlets. Glue may run down into the valve and interfere with valve operation. Allow glue
to dry for at least two hours before operating or testing the valve. For best results, use a multipurpose glue which is compatible with ABS plastic.
To seal off any unused outlets, install a piece of PVC pipe at least six inches in length to the outlet and cap the pipe. This will allow additional zones to be added eas-
ily at a later time. Make sure proper cam is installed for number of zones to be used.
Limited Warranty
paragraph above is in lieu of all other warranties expressed or implied; and we
do not authorize any representative or other person to assume for us any other
liability in connection with our products.
Contact manufacturer at, 3649 Cane Run Road, Louisville, Kentucky 40211,
Attention: Customer Service Department to obtain any needed repair or
replacement of part(s) or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED
OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS
FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE
LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied warranty, so
the above limitation may not apply to you. Some states do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other rights
which vary from state to state.
Major Components
Cam Replacement Instructions
Valve Installation Instructions
© Copyright 2019. All rights reserved.
2