Lenovo B6510 Manual del producto - Página 4

Navegue en línea o descargue pdf Manual del producto para Interruptor Lenovo B6510. Lenovo B6510 25 páginas.

Lenovo B6510 Manual del producto

System specifications

The following table lists the Lenovo B6505 and B6510 system specifications.
Table 1. System specifications
Component
Specification
Form factor
Standalone or 1U rack mount
Ports
Media types
8 Gb FC and 16 Gb SFP+ transceivers: short-wave (SW), long-wave (LW), extended
long-wave (ELW).
10 Gb FC SFP+ transceivers (Lenovo B6510 only; require Integrated 10G FC license): short-
wave (SW), long-wave (LW).
Port speeds
2/4/8 Gbps auto-sensing, full-duplex (8 Gb FC SFP+ transceivers)
4/8/10 Gbps auto-sensing, full-duplex (10 Gb FC SFP+ transceivers; Lenovo B6510
only)
4/8/16 Gbps auto-sensing, full-duplex (16 Gb FC SFP+ transceivers)
FC port types
Full Fabric mode: FL_Port, F_Port, M_Port (Mirror Port), E_Port, D_Port (Diagnostic
Port).
Access Gateway mode: F_Port and NPIV-enabled N_Port.
Data traffic types
Unicast (Class 2 and Class 3), multicast (Class 3 only), broadcast (Class 3 only).
Classes of service Class 2, Class 3, Class F (inter-switch frames).
Standard software Full Fabric mode, Access Gateway, Advanced Zoning, Adaptive Networking, Advanced
Diagnostic Tools, Virtual Fabrics (Lenovo B6510 only), In-flight Compression (Lenovo B6510
only), In-flight Encryption (Lenovo B6510 only).
Optional software ISL Trunking, Fabric Vision, Extended Fabric, Integrated Routing (Lenovo B6510 only),
Integrated 10G FC (Lenovo B6510 only).
Performance
Non-blocking architecture with wire-speed forwarding of traffic:
Scalability
Cooling
Two fans built into each power supply; 2+2 cooling redundancy with two power supplies. Non-
port to port side airflow.
Power supply
Up to two redundant hot-swap 150 W AC (100 - 240 V) power supplies (IEC 320-C14
connector).
Lenovo B6505 and B6510 FC SAN Switches
B6505: Up to 24 SFP/SFP+ ports. 12 ports licensed by default; 12x 8 Gb or 16 Gb FC
SWL SFP+ modules included with the switch; optional 12-port activation bundle
(license pack + 8 Gb or 16 Gb FC SWL SFP+ modules).
B6510: Up to 48 SFP/SFP+ ports. 24 ports licensed by default; up to two optional 12-
port activation bundles (license pack + 8 Gb or 16 Gb FC SWL SFP+ modules).
2.125 Gbit/sec line speed, full duplex
4.25 Gbit/sec line speed, full duplex
8.5 Gbit/sec line speed, full duplex
10.51875 Gbit/sec line speed, full duplex (Lenovo B6510 only)
14.025 Gbit/sec line speed, full duplex
Aggregated throughput
B6505: 384 Gbps
B6510: 768 Gbps
Up to 0.7 microseconds local switching latency
Forward error correction (FEC): Adds up to 0.4 microseconds between E_Ports
Encryption/compression: Adds up to 5.5 microseconds per node
Maximum number of switches in the fabric: 239
Maximum frame size: 2,112-byte payload
Maximum number of frame buffers per switch: 8,192
Maximum number of ports per ISL trunk: 8 (Requires an optional license)
4