CTX MyPool pH Manual - Página 3
Navegue en línea o descargue pdf Manual para Controlador CTX MyPool pH. CTX MyPool pH 12 páginas.
MyPool | pH · ORP
3. ELECTRICAL CONNECTIONS
Connect the power supply cable to the mains and the servocontrol pre-wired cable to the auxiliary contact of the
filter box (230 Vca).
1
Wiring diagram:
1. Input Level Probe (Product Tank)
2. RS485 Serial Port (connection to Fluidra Connect pool automation, optional)
3. Input Temperature Probe (PT100 sensor not included)
4. Output Relay Auxiliary Pump (Dry contact, Relay 250 Vac 10 A)
5. Output Relay Alarm remote (Dry contact, Relay 250 Vac 10 A)
4. TECHNICAL SPECIFICATIONS
Specifications
Measure Range
Set Point Range
Accuracy
Resolution
Power supply
Insulation class
Consumption
Pump flow rate
Max. back-pressure
Probe calibration
Pump state
Peristaltic tube
(ID x OD mm)
Dimensions
(H x W x D mm)
Weight
0000138876
2
3
4
MyPool pH
0.0 ÷ 14.0 pH
6.8 ÷ 7.8 pH
± 0.04 pH
0.01 pH
rev. 1.3
5
Recirculating pump
230V
230 VAC 50/60 Hz
II
10 W
1.6 l/h
1.5 bar
Automatic – Reference
Proportional dosing
Norprene 4.8 x 8 mm
185 x 124 x 110 mm
1.0 kg
EN
2 wires
3 wires
MyPool ORP
-99 ÷ 999 mV
300 ÷ 900 mV
± 2 mV
1 mV
3
3