Acorn Safety S0480 Instrucciones de instalación, uso y mantenimiento - Página 2
Navegue en línea o descargue pdf Instrucciones de instalación, uso y mantenimiento para Lavadora Acorn Safety S0480. Acorn Safety S0480 6 páginas. Wall mount shrouded eye/face washes
Installation & Operation Manual
PRELIMINARY STEPS
1. Read the installation instructions prior to beginning the installation.
2. Separate parts from packaging and verify all necessary parts are accounted for and undamaged. Obtain missing or
damaged parts from Acorn Safety prior to beginning installation.
3. Flush water supply lines prior to installation. This will remove unwanted debris from the lines and prevent unwanted
blockages in the safety equipment.
4. In order to comply with ANSI Z358.1, the safety equipment must be inspected periodically. An inspection tag is
provided for documentation purposes.
5. All employees at risk of injury/contamination should be informed and trained in the use of this and any other safety
equipment. The signage provided should be highly visible, posted in a well lit area within the area served by the
safety station.
ROUGH-IN FOR MODEL S0470/S0480
8 5 8 "
[219]
14 1 2 "
[368]
5 7 8 "
[149]
11 3 4 "
[298]
3 1 2 "
[88]
10"
[254]
1 3 8 "
A
3 3 8 "
[36]
[86]
A
1-1/4" [38] OD WASTE OUTLET
B
1/2" NPT SUPPLY INLET
GENERAL DIMENSIONS:
1. ALL DIMENSIONS ARE IN INCHES [MM].
2. REFER TO ADA FOR CLEAR FLOOR/GROUND SPACE AND APPROACH REQUIREMENTS.
*3. ANSI Z358.1 REQUIRES NOZZLES TO BE MOUNTED BETWEEN 33" - 45" [838 - 1143] ABOVE THE FINISHED
FLOOR.
4. ANSI Z358.1 REQUIRES A MINIMUM DISTANCE OF 6" [152] FROM WALL OR OBSTRUCTION.
Acorn Safety
a division of Acorn Engineering
Manual #7109-103-001
Ø12" [Ø305] MIN
FROM WALL OR
OBSTRUCTION
4 7 8 "
[124]
*33" - 45"
[838 - 1143]
B
Company
™
Page 2 of 6
6 1 4 "
[159]
23 7 8 " [606]
7
8 "
MIN FOR ANSI
[22]
1 5 8 "
[41]
10 7 8 "
[276]
5 5 8 " [142] TO
SUPPLY INLET
C
Ø1/4" [6] OD MOUNTING HOLE
D
Ø1/4" x 1-1/4" LONG [Ø6 x 38 LONG]
MOUNTING SLOTS
D
4 7 8 "
C
[124]
Revised: 05/06/13