MP_UVC_Instructions_AW.qxd
15/3/06
INSTALLATION
TESTING/REPLACING THE UVC LAMP
IMPORTANT:
Ensure that the mains supply is switched off and the power isolated before
removing the UVC cover.
1.
Unscrew the UVC electronics cover cap.
2.
Inspect the UVC cap and Quartz sleeve for water leaks.
3.
If there are no signs of leakage reverse the procedure ensuring that the Cover O-ring is in place.
If there has been any damage to the unit please return to the point of purchase for
inspection. This test should be repeated whenever the the bulb or quartz is changed.
Warning direct exposure to UVC light can damage your eyes or skin.
This unit is protected by a micro switch that prevents the UVC light from
illuminating when the cover is removed even if the power is on.
In order to check that the UVC lamp is operating remove
the hosetail and hold a piece of plain paper up to
the the UVC outlet a faint blue reflection should
be seen.This operation may need to be
carried out at dusk as UVC lamps emit a
dim blue light under normal operation.
ELECTRICAL INSTALLATION
Electrical installation - UVC
The power supply must meet the specifications on the product.
The UVC is intended to be used with either a weatherproof cable connector or permanently
connected to the fixed wiring in the main system other than by means of a plug and socket.
The cores in the supply cable are coloured in accordance with the following code:
Brown = Live, Blue = Neutral.
Do not use the supply cable to lift the UVC as this may cause damage.
WARNING -
A Residual Current Device (RCD), also known as the Residual Current
Circuit Breaker (RCCB), with a tripping current not exceeding 30mA must be installed in the
supply circuit. A means of disconnection from the supply having a contact separation of
at least 3mm in all poles must be incorporated in the wiring.
6
10:33 am
Page 5
2
3
2
ELECTRICAL INSTALLATION
IMPORTANT:
Please note all electrical work on garden lighting and power installations must comply
with part P of the building regulations. Failure to comply is a criminal offence. If the installation of this
product is not carried out by a competent electrician who is registered under the Part P self-certification
scheme then you must notify the local building control department before work begins. For further
information and guidance on this matter and other electrical installations in your home that might
be covered by the relevant legislation, contact your local authorities building control department.
For permanent installations to the mains supply, it is necessary to conform to the regulations of the local
electricity authority and this would include the use of a metal or plastic conduit to protect the cable.
Attention has been drawn to the fact that special rules may exist concerning the installation of your
1
pond UVC (i.e. local building regulations).
This UVC must not be used in swimming pools, or areas where people are in contact with the water.
Always disconnect the mains electricity supply whilst the equipment is being installed, repaired, maintained
or handled. Consult a qualified electrician if in any doubt about wiring this product to the mains supply.
Electrical/Safety
UVC Warning: Caution - Dangerous Ultra Violet Radiation. The rays from the UVC lamp
are harmful to eyes and skin.
Always turn off UVC electrical supply before any maintenance.
To protect unit from flooding, leave a minimum 5cm showing above ground level to protect UVC electrics.
Never immerse unit in water.
Locate unit 1m minimum from pond edge to ensure the UVC cannot fall in.
MAINTENANCE & CLEANING
Annual maintenance
Check for wear
Once a year you should dismantle your Minipond UVC. Dismantle the UVC examining all the parts for
wear or damage, replacing any parts show obvious signs of wear or damage. (see getting to know your
Minipond UVC for replacement codes and parts descriptions on page 2).
Winter storage
The UVC can be run year round if the pump flow is maintained, this is the best option. Alternatively in
winter the UVC may be switched off. Follow annual maintenance procedure and store frost-free in the
house or garage until spring.
7