Blagdon PRO UVC 21600 Manual principal - Página 7

Navegue en línea o descargue pdf Manual principal para Sistemas de filtración de agua Blagdon PRO UVC 21600. Blagdon PRO UVC 21600 8 páginas. Green water clarifier

Blagdon PRO UVC 21600 Manual principal
UVC_Pro_Inst_AW.qxd
5/2/08
11:33

ELECTRICAL INSTALLATION

Electrical installation - UVC
The power supply must meet the specifications on the product.
The cores in the supply cable are coloured in accordance with the following code:
Brown = Live, Blue = Neutral.
Do not use the supply cable to lift the UVC as this may cause damage.
WARNING -
A Residual Current Device (RCD), also known as the Residual Current
Circuit Breaker (RCCB), with a tripping current not exceeding 30mA must be installed in the
supply circuit. A means of disconnection from the supply having a contact separation of
at least 3mm in all poles must be incorporated in the wiring.
IMPORTANT:
Please note all electrical work on garden lighting and power installations must comply
with part P of the building regulations. Failure to comply is a criminal offence. If the installation of this
product is not carried out by a competent electrician who is registered under the Part P self-certification
scheme then you must notify the local building control department before work begins. For further
information and guidance on this matter and other electrical installations in your home that might
be covered by the relevant legislation, contact your local authorities building control department.
For permanent installations to the mains supply, it is necessary to conform to the regulations of the local
electricity authority and this would include the use of a metal or plastic conduit to protect the cable.
Attention has been drawn to the fact that special rules may exist concerning the installation of your
pond UVC (i.e. local building regulations).
This UVC must not be used in swimming pools, or areas where people are in contact with the water.
Always disconnect the mains electricity supply whilst the equipment is being installed, repaired, maintained
or handled. Consult a qualified electrician if in any doubt about wiring this product to the mains supply.
Electrical/Safety
UVC Warning: Caution - Dangerous Ultra Violet Radiation. The rays from the UVC lamp
are harmful to eyes and skin.
Always turn off UVC electrical supply before any maintenance.
To protect unit from flooding, leave a minimum 5cm showing above ground level to protect UVC electrics.
Never immerse unit in water.
Locate unit 1m minimum from pond edge to ensure the UVC cannot fall in.
10
Page 7
MAINTENANCE & CLEANING
Annual maintenance
Check for wear
Once a year you should dismantle your PRO UVC. Dismantle the UVC examining all the parts for wear
or damage, replacing any parts show obvious signs of wear or damage. (see getting to know your
PRO UVC for replacement codes and parts descriptions on pages 2 and 3).
Winter storage
The UVC can be run year round if the pump flow is maintained, this is the best option. Alternatively in
winter the UVC may be switched off. Follow annual maintenance procedure and store frost-free in the
house or garage until spring.
TROUBLESHOOTING
In order to correctly identify if you have green water or cloudy/brown water, a settlement
test should be carried out.
Take a glass of pond water and allow to settle for a few hours. When the glass is stirred a
small layer of settled waste can be seen at the base of the glass. This indicates that you have
brown or cloudy water and that your UVC is working correctly. If there is no settlement it
indicates that you have green water and the UVC is not working correctly.
UVC leaks
Check that the UVC inlet/outlet caps and O-ring have been correctly assembled and that they are
hand tight.
PTFE tape may be needed to give a water tight seal and should be applied to the inlet or outlet hosetails.
Always secure the UVC inlet hose and outlet hose with a jubilee clip.
11