Figure 3
Product discharged from exhaust outlet.
Check for diaphragm rupture.
Check tightness of (6) diaphragm washer.
Air bubbles in product discharge.
Check connections of suction plumbing.
Check O" rings between intake manifold and inlet side
fl uid caps.
Check tightness of (6) diaphragm washer.
Motor blows air or stalls.
Check (176) check valve for damage or wear.
Check for restrictions in valve / exhaust.
PD10P-X
PARTS LIST / PX10P-X AIR SECTION
173
118
169
174
121
167
140
141
233
Notch
200
Insert screwdriver here to remove (233) adapter plate.
138
139
MAJOR
VALVE
A replacement Major Valve Service Assembly is available separately, which includes the following:
637395-1 for models PD10P-X: 105 (4), 107 (2), 111, 132, 135, 136, 137, 138, 139, 140, 141, 166,
176 (2), 200, 233 and 236 (4)
637395-2 for models PE10P-X: 76, 105 (4), 107 (2), 111, 132, 135, 136, 137, 138, 139, 140, 141, 166,
176 (2), 200, 233 and 236 (4)
TROUBLE SHOOTING
168
172
171
170
166
132
176
101
181
TORQUE REQUIREMENTS
NOTE: DO NOT OVERTIGHTEN FASTENERS.
ALL FASTENERS ARE METRIC.
Torque (105 and 134) screw to 35 - 40 in. lbs (4.0 - 4.5 Nm).
LUBRICATION / SEALANTS
Apply Lubriplate FML-2 grease to "O" rings, "U" Cups & mating parts.
Apply anti-seize compound to threads at assembly.
Low output volume, erratic fl ow, or no fl ow.
Check air supply.
Check for plugged outlet hose.
Check for kinked (restrictive) outlet material hose.
Check for kinked (restrictive) or collapsed inlet material
hose.
Check for pump cavitation − suction pipe should be sized
at least as large as the inlet thread diameter of the pump
for proper fl ow if high viscosity fl uids are being pumped.
Suction hose must be a non-collapsing type, capable of
pulling a high vacuum.
Check all joints on the inlet manifolds and suction con-
nections. These must be air tight.
Inspect the pump for solid objects lodged in the dia-
phragm chamber or the seat area.
PILOT VALVE
PART GROUP
173
118
121
174
103
201