Aroma360 Museum360 Manual de solución de problemas
Navegue en línea o descargue pdf Manual de solución de problemas para Accesorios Aroma360 Museum360. Aroma360 Museum360 2 páginas.
También para Aroma360 Museum360: Manual (2 páginas)
Problem
Scent Too Strong or Too Soft
Not Scenting
No LCD Indication
Oil Leaking
Oil in Tubing
Buttons are not working
Solution
Increase scent level by pressing "mode" three times and a number will appear that represents the scent level as
a percentage. Use the up arrow to increase the intensity. Use the down arrow to decrease the intensity. Once
adjusted, press "mode" three more times to adjust any other operating intervals.
Make sure power cord is plugged into wall and unit and the unit is powered on.
Make sure the display does NOT say "CLOSE, OFF" or "WORK, PAUSE" because that means the unit is not set to
be working at that time.
Display must say "WORK, ON" for the scent to disburse.
Put ½ an inch of rubbing alcohol in an empty bottle and run it through the machine for 5 minutes. Discard the
alcohol and replace with your favorite Aroma360 scent.
Power is not getting to the unit or the unit is turned o
The oil bottle is loose or screwed in incorrectly.
The thick tubing that goes into the duct has a bend/curvature or is directing the scent downwards. The thick
tubing must point upwards from the atomizer and go straight into the duct
Ensure there are no kinks/curves in the thick tubing that goes into the duct. That tubing must be pointed directed
upwards into the duct and must be in a straight line.
The fan setting on the thermostat may be set to "auto" as opposed to "always on" . You may have either AC or heat
running but the fan needs to be on while the di user is scheduled to be working
The unit settings may be locked. Hold down the "SET" button for ten seconds until you hear a beep. The sound will
indicate "lock mode" has been disable.