Instruction manual condensation dryer DH 10 / DH 20
The dryer does not achieve
the humidity adjusted at the
hygrostat and/or does not
switch itself off via the
hygrostat.
Attention!
The appliance must be repaired by a trained and expert personnel only. In the case of
interventions by unauthorized people, any and all warranty claims shall become null and void!
If you have any questions regarding defects and malfunctions of AERIAL-air dryers we
recommend to get in touch with your supplier.
from Serie July 2003
15
The hygrostat is adjusted
onto a value below 45% r.h..
16
The unit is to small for your
application
17
Im Raum, in dem das Gerät
im Einsatz ist, herrschen
Temperaturen unter 15°C
18
There is a lot of moist in the
walls and in the floor
(Building materials) .
19
A mistake at the hygrostat is
possible.
20
A mistake in the cooling
circuit of the dryer is
possible..
page 10
AERIAL GmbH
A condensation dryer can achieve
- depending on environmental
conditions - at a minimum a value
from 40 to 45% r.h. . Put the built-
in hygrostat on an attainable value
(e.g. approx. 50%r.h.), with it that
dehumidifier punctual may switch
off.
The air changing rates, persons in
that room and open water
surfaces decide on the humidity
load. Ask your authorized dealer
to calculate if the unit has enough
capacity for your application.
Da die Entfeuchtungsleistung der
DH-Serie bei kühlen Bedingungen
aufgrund der Auslegung der
Kältekomponenten und aufgrund
der Luftabtauung nicht optimal ist,
empfehlen wir den Einsatz dieser
Geräte nur in beheizten Räumen
mit Temperaturen >= +15°C.
In this case, the dryer needs
some time to remove all that
water and to achieve an
acceptable humidity in that room
Check the hygrostaten: Does the
unit siwtch off when you dial the
knob to „O" ? If it does not switch
off, there is a mistake. Contact
your supplier.
Check whether water gathers in
the water tank. If this is not the
case although the compressor ran
permanently, you should get in
touch with your supplier.