Determining the end run points
During opening:
- Fully open the leafs (the maximum aperture is 110 °);
- loosen the screw (1) until it makes contact with the body (3);
- tighten the nut (2) to lock the position of the screw.
During closing:
- close the leaves completely;
- loosen the screw (1) until it makes contact with the transmission arm (2);
- tighten the nut (3) to lock the position of the screw.

ELECTRICAL CONNECTIONS

For electrical connection operations, see the control panel technical documentations.
Gearmotor
FROG-PM4
FROG-PM6

FINAL OPERATIONS

Securing the cover

Rest the cover on the foundation box and secure using the screws (supplied)