Aeris SmartSense Manual de depuración - Página 4

Navegue en línea o descargue pdf Manual de depuración para Monitor Aeris SmartSense. Aeris SmartSense 4 páginas.

Aeris System Debugging Guide
8. If the system has consistently taken air on a particular wheel end on a number of recent trips then
the severe alert indication or maintenance alert triangle will be given on the display and will remain
on until the system has completed a couple of trips without taking air. This icon stays on even when
the system is not powered
If the severe alert icon or maintenance alert is turned on then there is either a leak
in the system or a wheel end has a tire problem that will continue to get worse if it
is not repaired.
The maintenance alert will not clear until the system has been error free for 1 entire
day and at least 2 power on events have occurred.
9. If the light goes out after the first 3 blinks after a power on event and the error condition is "0" then
all is ok and tires are aired up. A green light will be blinking in the control box in this condition acting
as an "I'm alive" indicator.
d
August 2015
Page 4 of 4