Cameron Pow-R-Seal WKM 58G Manual de instalación, uso y mantenimiento - Página 17

Navegue en línea o descargue pdf Manual de instalación, uso y mantenimiento para Unidad de control Cameron Pow-R-Seal WKM 58G. Cameron Pow-R-Seal WKM 58G 20 páginas. Gate valve

Trouble
(continued)
Motor operator will not
actuate valve.
Valve operation is erratic.
The valve seats will not
seal.
Contact loacal Cameron Valves & Measurement Representative for current part number
1
Pressure locked is a condition that may exist in any double sealing gate valve when the body cavity pressure greatly exceeds line pressure. It occurs only in the
2
full open or full closed position and indicates that the sealing surfaces are in good condition.
Installation, Operation and Maintenance Manual
Probable Cause
(continued)
Improperly sized motor operator.
Improperly wired electric operator.
The bearings need lubrication.
The bearing or gear unit is broken
or damaged.
Valve is not fully closed.
Seat or seat seals are damaged.
17
E N G I N E E R E D & P R O C E S S V A L V E S
Remedy
(continued)
Replace with properly sized motor operator.
Verify wiring following instructions and schemat-
ics provided by the operator
manufacturer.
Lubricate bearings per the Routine Maintenance
Section.
Replace broken or damaged parts.
Fully close the valve. Turn the handwheel CLOCK-
WISE. DO BACK OFF
THE HANDWHEEL.
Lubricate seats per Routine Maintenance Section.
Replace parts.
02/2011 / IOM-WKM-GATE-PRS-01