Installation Manual
Fiber Splicing
1.
Route the buffer tube to be spliced in the slack
storage area and up to the cassette to be spliced.
2.
Mark the tie off point of the cassette with a marker.
Make sure to leave around 3 feet of extra buffer tube
after the mark to allow for slack in the cassette's
splice tray.
3.
Remove all Clearview Blue Cassettes from the wall
box that need to be spliced. This can be done by
opening the bulkhead and loosening the captive
screws on each side of the cassette which hold the
cassette to the bulkhead.
4.
Consult the Clearview Blue Cassette Installation Manual for splicing instructions, located under the Resources tab of
the Clearfield website, www.seeclearfield.com.
Viewable here:
https://www.seeclearfield.com/assets/documents/installation-manuals/clearview-blue-cassette-install-manual.pdf