ESI ESCTDE Manual de instrucciones de uso e instalación - Página 13
Navegue en línea o descargue pdf Manual de instrucciones de uso e instalación para Termostato ESI ESCTDE. ESI ESCTDE 16 páginas. Electronic dual cylinder thermostat
Fitting the Cylinder Thermostat
1. Slacken the three fixing screws, and insert both sensors fully into the pocket.
2. Position the thermostat onto the pocket.
3. Tighten the three screws to secure the thermostat, take care not to over
tighten.
4. Complete the wiring connections.
Adjusting and Resetting the Cylinder Thermostat
Adjust the dial to show the desired hot water temperature on the display,
between 25
C to 65
C. Remember, the lower the temperature, the less chance of
o
o
scalding, and the more energy saving. Most home owners find a temperature of
around 48
C - 53
C to be adequate.
o
o
If the system should overheat, the cause must be determined and resolved by a
suitably qualified person. In the event of an overheat, the thermostat cuts out
automatically. The reset for the thermostat is under the adjustment dial.
8