Alto-Shaam HALO HEAT HOT 2GO Manual de uso y mantenimiento - Página 7

Navegue en línea o descargue pdf Manual de uso y mantenimiento para Comerciante Alto-Shaam HALO HEAT HOT 2GO. Alto-Shaam HALO HEAT HOT 2GO 13 páginas. Hot merchandiser

Alto-Shaam HALO HEAT HOT 2GO Manual de uso y mantenimiento
This chart is provided for the assistance of qualified technicians only and is not intended for use by untrained or
unauthorized service personnel. If your unit is not operating properly, check the following before calling your
authorized service agent. Check the power applied to the unit. Plug in outlet? Fuse OK?
Do not attempt to repair or service beyond this point. Contact manufacturer for nearest authorized service agent.
Repairs made by any other service agent without prior authorization by manufacturer will void the warranty on the unit.

Error Code

1. Control displays "OOO".
INCREASE/DECREASE
HEAT
ROCKER BUTTON
L.E.D.1
INDICATOR L.E.D.
ooo
prg
SET
!
°F
ERROR CODE
ERROR
TEMPERATURE
INDICATOR L.E.D.
CODE
SET
DISPLAY
BUTTON
2. Control displays "CCC".
INCREASE/DECREASE
HEAT
ROCKER BUTTON
L.E.D.1
INDICATOR L.E.D.
CCC
prg
SET
!
°F
ROCKER SWITCH
ERROR CODE
ERROR
TEMPERATURE
INDICATOR L.E.D.
CODE
SET
DISPLAY
BUTTON
3. Unit does not operate.
4. No display in electronic control.
5. Cannot control temperature but sensor
and electronic control check OK.
6. Temperature readout incorrect.
DISCONNECT UNIT
FROM POWER SOURCE BEFORE
CLEANING OR SERVICING.
Tr o u b l e S h o o t i n g G u i d e
Possible Cause
A. Sensor is open circuited.
B.
Associated wiring is open circuited.
POWER
ON/OFF
ROCKER SWITCH
C. Control is faulty.
A.
Sensor is short circuited.
B.
Associated wiring is short circuited.
POWER
ON/OFF
C. Control is faulty.
A.
Insufficient power supply.
B.
Defective power cord or plug.
A.
Faulty power supply board.
B.
Faulty electronic control
A.
Faulty relay.
B.
Heating element sensor.
A.
Dirty or faulty sensor.
B.
Faulty control.
Operation & Care Manual #835 • 6.

Action Required

Detach the sensor from the terminal block.
SENSOR
Use an Ohm meter to measure the resistance
of the sensor. Check sensor at 32°F (0°C)
using a container of ice water. If Ohm read-
EXT. WIRES
T-BLOCK
CONNECTORS
ing is 100, replace display. If Ohm reading is
not 100, replace sensor.
Check wires for integrity. Check for proper
and secure connections at the thermostat and
terminal block. If necessary, re-secure the
faulty connections.
Energize system after the above steps have
been completed. If control still reads
"OOO", contact factory.
Detach the sensor from the terminal block.
SENSOR
Use an Ohm meter to measure the resistance
of the sensor. Check sensor at 32°F (0°C)
using a container of ice water. If Ohm read-
EXT. WIRES
T-BLOCK
CONNECTORS
ing is 100, replace display. If Ohm reading is
not 100, replace sensor.
Check wires for integrity. Check for proper
and secure connections at the thermostat and
terminal block. If necessary, re-secure the
faulty connections.
Energize system after the above steps have
been completed. If control still reads
"CCC", contact factory.
Check power source.
Check and replace if necessary.
Check line voltage for 24V across pins 6 and
7 on the power supply board.
Replace control.
Replace relay.
Replace element.
Detach the sensor from the terminal block.
Use an Ohm meter to measure the resistance
of the sensor. Check sensor at 32°F (0°C)
using a container of ice water. If Ohm read-
ing is 100, replace display. If Ohm reading is
not 100, replace sensor.