Altra Industrial Motion Warner Electric PB-400 Manual de instrucciones de instalación - Página 10

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Equipamiento industrial Altra Industrial Motion Warner Electric PB-400. Altra Industrial Motion Warner Electric PB-400 18 páginas. Primary brakes

Send Quote Requests to [email protected]
PB-120 Brake
For Bore sizes
see chart below .
Std . Armature
Antibacklash
Armature
Armature View
1 .125 Max . Sq .
Magnet View
*Mounting holes are within .006 of true position relative to pilot
diameter .
Customer Shall Maintain:
1 . Concentricity of brake mounting pilot diameter with
armature shaft within .003 T .I .R .
2 . Squareness of brake mounting face with armature
shaft within .003 T .I .R .
10 Warner Electric • 800-825-9050
1 .499/1 .497 Pilot Diameter
45°
.130/ .123 dia . (4)
holes equally spaced
on 1 .312 diameter*
Send Quote Requests to [email protected]
Call +1(800)985-6929 To Order or Order Online At Warnerelectricparts.com
Call +1(800)985-6929 To Order or Order Online At Warnerelectricparts.com
.015 When New
.072 (Std .)
.072 (Anti .)
12
.109 (Std .)
.140 (Anti .)
.500
1 .234
Std . Arm .
Max .
Dia .
Anti Arm .
.562
.072 (Std .)
.072 (Anti .)
.343
.015
.968 Max .
Bore Di men sions
Armature Bore Dia.
.188/ .187
.251/ .250
( .313/ .312)*
*(Antibacklash Armatures)
Shaft Sizes
Static Torque
Maximum Speed
Standard Voltage
.312
.062
.375 Dia .
#4-40
UNC-3A
.187
Max .
.625
.187 – .250
5 lb . in .
10,000 rpm
D .C . 6, 24, 90
P-201-WE • 819-0480