END PANEL INSTALLATION
The following procedure describes installing an end panel
that includes D-rings at the top and horizontal pocket heat
sealed to the lower inside surface of the panel.
Additional purchase is required for end panel and end
panel installation kit. Complete these steps to install an
end panel of this design.
Required parts include:
•
End panel
•
131S075 Pipe (kit)
•
QH1061 Ratchet & 103620E 1" strap (kit)
•
FAMF01B Washers & FA4482B Tek screws (kit)
1. Position the panel flat on ground with the long edge
against the bottom end wall frame member and the
pocket facing up. (The pocket and D-rings should be
visible when the panel is positioned properly.)
2. Locate D-rings near top edge of panel and tie a section
of strapping (or rope) to center-most D-ring. Tie two
additional straps on each side of the center D-ring,
allowing a few feet to remain between the straps.
Revision date: 11.12.14
DO NOT ATTEMPT
TO PULL THE END
PANEL INTO POSITION
ON WINDY OR STORMY
DAYS!
CLEARSPAN
3. With the temporary straps (or customer-supplied rope)
in place, pull the end panel up to the end rafter and
secure the end panel to the end rafter using small
sections of the strap. Keep the panel centered.
Outside of the End Panel
NOTE: Pull top edge of end panel toward rafter.
(Approximately 1 to 2 feet of the end panel material will
remain at and run along the base of the end wall. In a
later step, this can be secured to the bottom tube of the
end wall frame, if equipped. Or, it can remain as a skirt
to direct water away from the shelter.)
The end panel must touch the ground after the top
edge of the panel is secured to the rafter. Adjust panel
and strap as needed.
Top Chord of the
End Rafter
Strap in D-ring
End Panel
View (above) is from the inside of the shelter looking
at the end panel. Frame and rafter shown are different
from your frame. The technique used to secure the
end panel is the same however. Photo shows the main
cover installed.
END WALL FRAMING KITS
™
Main Cover
7