Periodically check the unit intake vent holes for the unlikely event of debris accumulation. It is
important these vent holes are open for air to enter the ozone unit. Do not look directly into the
vent holes when the UV bulb is operating.
Plumbing Issues
Minor adjustment of the ball valve (when installing the manifold) may be required to divert water
through the injector. This may be true with two speed or variable speed pumps. Older versions of
these adjustable speed pumps do not adjust well and you will need to adjust the ball valve to
accommodate flow through the venturi on low speed.
There is an internal check valve in the venturi injector. In the unlikely event this area becomes
clogged, it may be cleaned by removing the nut/barb and a retaining rubber seal. Care should be
used not to lose the internal ball and spring while taking the rubber seal off. Clean and reinstall.
K. Scheduled Maintenance & Replacing the UV Bulb
There is very little maintenance required with the OzoneMAX unit, however we do recommend you
replace the ozone hoses and check valves once a year.
Replace ozone hose once a year
Order replacement part – OZ-HOSEKIT –
from your dealer. This complete package includes 8 feet of hose, two check
valves, 6 hose clamps, and 5 zip ties.
Replacing the UV Bulb
Order replacement part – OZ-50/75L –
Replacement OZ-50 bulb – from your dealer.
Replace the UV bulb after approximately 9,000 hours of use. This is approximately 3 years of running the
ozone unit 8 hours a day, 365 days a year. We recommend the bulb gets changed at about 70% of its life for
optimum performance, or the 9,000 hours. To determine the actual number of hours the ozone system has
been running, simply calculate the number of days your pool is open a year by the number of hours per day the
equipment is running. When the bulb does lose its power, you will notice the water getting cloudier quicker or
having to use more chlorine than usual. You can also check the clear connector on the output tube of the
power box. It should be a glowing blue in color if the bulb is on. Note: It is much easier to view this indicator
feature in the evening hours when there is no bright sunlight.
When replacing the UV bulb, we strongly recommend you remove the unit from the wall. This is to insure you
carefully remove the delicate equipment from the metal enclosure properly, and seal back up tightly.
Bottom of unit with
bottom panel off
Replacing the bulb in the OzoneMAX unit.
1. Disconnect power from the OzoneMAX unit. Coming into contact of the exposed ozone bulb can
cause serious damage to your health.
2. Remove the six (6) screws on the bottom of the unit.
J. Periodic Inspection
Metal plate with the bulb
ballast attached to it
Zip tie holding in bulb
(continued)
Cut zip tie
Carefully remove bulb from
holding in bulb
metal bracket & white connector