ClearWave Air CWA200 Manual del usuario - Página 11

Navegue en línea o descargue pdf Manual del usuario para Limpiador de aire ClearWave Air CWA200. ClearWave Air CWA200 12 páginas.

5. Continue wearing gloves. Insert the new lamp into the UV chamber with the groove of the end cap
aligning with the notch in the UV chamber. This will allow the two lamp pins to align with the pin
receptacles in the bottom of the UV chamber. When you are sure that the lamp is properly aligned,
lightly press down on the lamp until you hear a 'click.' This means that the lamp is properly installed.
6. You are now ready to reassemble the unit. Insert the top cap into the aluminum body so that the screw
holes in the aluminum line up with the threaded holes in the top cap. Reinsert the screws and plug
in the power supply. If your air purifier functions normally again, your lamp replacement has been
successful.
ClearWaveAir • 11