AIMS Power PWRI18012S Manual de instrucciones - Página 5

Navegue en línea o descargue pdf Manual de instrucciones para Inversor AIMS Power PWRI18012S. AIMS Power PWRI18012S 11 páginas. Dc to ac pure sine power inverter

AIMS Power PWRI18012S Manual de instrucciones
2. Battery operating time depends on battery capacity and load. The formula for
operating time is: battery capacity divided by the value of the load divided by
battery voltage times 1.10%. For example, using the numbers from above, the
battery specification is 12V, 200Ah capacity and the load is 1000W. Take battery
capacity 200Ah / 91.6 amps = 2.18 hours of run time if you fully deplete the
battery. This is NOT recommended. Deep cycle batteries last longer when they
are only depleted to 50% of capacity.
F. CONNECTION
1. Grounding
The power inverter has a terminal on the rear panel marked " Grounding "or " ".
This is used to connect the chassis of the power inverter to ground. The ground
terminal has already been connected to the ground wire of the AC output
receptacle through the inverter.
The ground terminal must be connected to the ground wire, which will vary
depending on where the power inverter is installed. In a vehicle, connect the
ground terminal to the chassis of the vehicle. In a boat, connect it to the boat's
ground system. In a fixed location, connect the ground terminal to earth.
2. Battery terminals
Before you connect the battery cables, make sure the power switch is in the off
position. Connect Red (+) battery cable to Red (+) inverter terminal. Connect
Black (-) battery cable to Black (-) inverter terminal. Connect Red (+) battery
cable to Red (+) battery terminal. Connect Black (-) battery cable to Black (-)
battery terminal. Alligator clamp cables may be used but only to connect to the
battery. Do not use clamps on inverter terminals. Alligator clamps are not a
permanent solution. You may see a spark during connection. Do not reverse the
polarity. This may damage the inverter and void warranty.
USING THE POWER INVERTER
1. Check the output voltage and capacity of the battery. The battery (s) should
match the voltage of the inverter and have enough capacity for the load. See
Section E for more information.
2. Connect your inverter to your battery bank and do not to reverse the polarities of
the connection. See Section F.
3. Press the power switch button on your inverter for .5 seconds and a green LED
will light up indicating that the inverter is on.
4. Before plugging anything into your inverter, make sure the appliance you are
trying to power is shut OFF, then plug it into the AC outlet of your inverter and
power on your appliance.
5