CALIBRATION INSTRUCTIONS
• Place the Pressure Plate, any D100 Series Standard Die Set and the Compression
Ring in the crimper in the order shown.
• Set the Micro-Crimp Adjuster as follows:
Standard Micrometer: "100"
"DC" Micrometer:
Metric Micrometer:
• Bring the ram and pusher down on top
of the compression cone and increase the
pump pressure until the die set is completely
closed and the pump starts to build pressure.
All D100 Series Crimpers
• Continue increasing the pressure on the
compression Cone until the circumferential
white line on the Micro-Crimp Sight Button just becomes
visible above the Micro-Crimp Adjuster as shown in the
illustration.
D101S Series Crimpers (with electric pump)
• The Electric pump should completely close the die set
before the pump shuts off .
• If the white line is not visible or the electric pump does not
shut off when the dies are completely closed, adjust
the calibration adjustment screw under the Micro-Crimp
Adjuster contact button as illustrated. Repeat the calibration
procedure until the above conditions are satisfi ed.
• When the above conditions are met, the crimper is
calibrated and ready for use.
"95"
"0"